13
Technical data boiling water storage heater:
• Connection:
wall socket with earth wire,
protected via a 10 A fuse
• Installation elevation:
max. 2000 m above sea level
• Voltage supply:
230 V AC / 50 Hz
• Max. power consumption:
2200 W
• Type of protection:
IP X4
• Relative humidity:
max. 95 %
• Ambient temperature:
0–40 °C
• Standby power loss (switched on):
14 W
• Standby power loss (holiday mode):
5 W
• Standby power loss (switched off):
1 W
• Energy efficiency class:
A
Sanitary data:
• Boiling water storage heater capacity:
4 l
• Available storage heater volume at 100 °C:
approx. 3 l
• Flow pressure:
- min.
0.2 MPa
- recommended
0.2–0.5 MPa
• Operating pressure:
max. 0.8 MPa
• Test pressure:
1.6 MPa
• Flow rate at 0.3 MPa flow pressure
- mixed water:
approx. 6 l/min
- boiling water:
approx. 3 l/min
• Boiling water temperature:
100 °C
The actual temperature may differ slightly
due to different ambient pressures.
• Heating time from 10 °C to 100 °C:
M: approx. 20 min
• Clamping length of fitting:
max. 60 mm
• Water connection to storage heater:
cold water
• Water connection fitting:
cold/hot water from the service valve
boiling water from storage heater
Thermal disinfection of the fitting is possible.
Confirmation
Installation and commissioning
Flush pipes thoroughly before and after installation
(observe EN 806)
!
Note: The volume of water in the storage heater will expand as
it is heated. The expansion water must drip out of the funnel of
the safety assembly.
This is a necessary and completely normal process.
Check all connections for leakage.
Retighten screw connections as necessary.
Operation
, see page 8.
Unlock the child lock to draw off boiling water, see
A
.
Drawing off cold or hot water, see
B
.
Activating holiday mode, see
C
.
Note
:
In order to prevent incorrect operation and for protection against
injury, we recommend affixing the sticker provided.
Maintenance and cleaning
CAUTION!
Risk of damage!
Always disconnect from the voltage supply
before
carrying out maintenance work on the system. The plug-in
connector can then be disconnected.
If work is performed on mains power supply or in case of
any maintenance work, the GROHE Red boiling system
must be bled as otherwise blasts of steam could form as a
result.
• Draw off boiling water from the storage heater until just cold water
flows.
• Close the service valve, switch off the storage heater and
disconnect the mains plug.
• Open the lever on the fitting and as well as the rotary knob on the
safety assembly to depressurise the storage heater.
• Drain the storage heater (not required each time maintenance is
performed): Remove the cap or hose to the mixing valve and
drain the storage heater using the connecting hose to the safety
assembly.
• Inspect and clean all parts, replace as necessary and lubricate
with special fitting grease.
Status
Storage heater LED
Initialisation
white
Heating phase
red, flashing
Ready for operation
red, continuous
Holiday mode, cooling-down
phase
orange, flashing
Holiday mode
orange, continuous
Defects
agenta, flashing/continuous
10
Содержание RED 30 392
Страница 2: ...1...
Страница 3: ...2 M GROHE Deutschland Vertriebs GmbH Zur Porta 9 D 32457 Porta Westfalica min 300...
Страница 4: ...3 35 34 1 2 4 19mm 19mm max 60mm 3 max 45mm...
Страница 5: ...5 17 19mm 14 30mm 19mm 19 13 18 24mm 15 12 min 50mm max 700mm 16 19mm 4...
Страница 6: ...6 20 21 22 2 90 sec 23 1 3 min 24 1 2 5...
Страница 7: ...8 A 1 2 B C max 60 C 1 3 2 4 6...