4
Automatic flushing
The automatic flushing serves to protect the water hygiene in
cases of longer non utilization the mixer and activates water
flow 1 or 3 days after the last use for 1 - 10 minutes.
Safety notes:
•
Guarantee free drain in the case of activated automatic
flushing.
With remote control (see special accessory, ref.-no.: 36 206)
the type of detection can be changed.
1.
Switch
automatic flushing
On / Off
.
•
Press and hold key
RESET
.
•
Pressing key
OFF AUTO
within 2 s.
(Control light in the sensor flushes).
-
Switch on:
pressing key
OFF AUTO
within 10 s
Control light in the sensor flushes 4 x short =
On
-
Switch off:
pressing key
OFF AUTO
within 10 s
Control light in the sensor flushes 2 x long =
Off
Leaving the adjusting mode automatically after 10 s.
2.
Change
flushing interval from
3
to
1 day
.
•
Press key
TEST
.
With the key
ON AUTO
the flushing interval can be setted.
•
Press key
ON AUTO
.
Control light in the sensor flushes:
-
2 x long
= 1 day
-
4 x short
= 3 days
Leaving the adjusting mode by pressing key
TEST
or
automatically after 60 s.
3.
Set flushing period from
1
to
10 minutes
.
•
Press key
TEST
.
With the keys
+
and
-
(key
) the flushing period can
be increased (
+
) or decreased (
-
).
•
Press key
+
or
-
(key
).
Control light in the sensor flushes:
-
4 x short
= shift one step (approx. 1 min.)
-
2 x long
= achieve the end position
Leaving the adjusting mode by pressing key
TEST
or
automatically after 60 s.
Replacement parts,
see fold-out page II ( * = special
accessories).
Care
For directions on the care of this mixer, please refer to the
accompanying Care Instructions.
Problem / Cause / Remedy
Problem
Cause
Remedy
Water does not flow
•
Water supply interrupted
•
Filter in the solenoid valve is clogged
•
No voltage (control light does not flash)
•
Solenoid valve defective
•
Electronics defective (control light, see
Fig. [10], does not flash or lights up
continuously)
•
Plug connectors of solenoid valve without
contact
•
Transformer defective (control light,
see Fig. [10], does not flash)
- Open stop valves, isolating valves
- Clean
- Switch on voltage supply, check patch cords
- Replace
- Replace
- Plug together plug connectors
Replace
Control light flashes
•
Cleaning mode activated
- End cleaning mode, see description
Water flows
continuously
•
Membrane is clogged
•
Solenoid valve defective
- Clean
- Replace
Water flows
inadvertently
•
The detect zone of the sensor extends
beyond the basin
- Reduce range with remote control
(special accessory, ref.-no. 36 206)
Quantity of water too
small
•
Filters, flow straightener are dirty or
membrane defective
•
Isolating valves not fully opened
•
Water supply throttled
- Replace
- Fully open stop valves, isolating valves
- Check supply pipes, open isolating valves