BreakAlube-3
F600775R00
24
Installation
Automatic Greasing System
Release date: September 2014
• Also check the grease pressure of the system. For this, a pressure gauge must be connected
to the pump as a standard, The pressure in the system must remain above the minimum set
grease pressure of 20 bar and below the maximum grease pressure of 275/300 bar during
every cycle to avoid an error being stored.
The counter-pressure of the connected grease hose is normally far higher than 20 bar , but
it is possible that with a small quantity of grease per cycle, this pressure is not yet reached
during the first few cycles after installation.
If the grease pressure rises to above 275/300 bar, an integrated safety valve should open
and relieve the excessive pressure to the grease reservoir. If the grease hose is clogged or
the quick coupler to the hydraulic hammer is not or not correctly connected, this pressure
should increase at each cycle until this maximum pressure is reached.
• Check the system one last time for leaks. If leaks are found, remedy these and thoroughly
clean the area of the leakage so that the client does not later get the impression that the
system is still leaking.
• Explain and demonstrate the function of the system to the client or machine dealer, if pres-
ent.
• Disconnect the UniGINA from the pump and connect the pump wiring harness directly to
the pump again.
• The system is now ready for operation.