3.6
The test push-button
The test push-button on the pump unit has 3 functions:
• Performing a test cycle.
• Resetting the signal lamp and pump after solving the
error(s).
• Retrieving error codes stored in the memory bank of the
control unit.
3.6.1 Performing a test cycle
A test cycle can be performed by using the test push-button, as follows:
1. The supply voltage for the pump unit must be available (ignition ON).
2. Push the test Push-button (less then one second) once to perform a test cycle. Provided
that the pre-set delivery amount is more than 0 cc.
3. After two seconds the test cycle starts.
During the test cycle the signal lamp will continuously flash once followed by a pause of two
seconds.
To end the test cycle immediately press the test push-button once.
Any errors that occur during the test cycle will not be indicated by the signal lamp and will
not be stored in the memory bank of the control unit.
ATTENTION
When the pump unit is already performing a pump phase, a test cycle
cannot be performed in this way.