22

i)

When the equipment needs to be sanitized,
use a sanitizing solution equivalent to one
that supplies 200 parts per million available
chlorine. Obtain advice on the best sanitizing
agent from your supplier of sanitizing
products. Following the suppliers
instructions, apply the sanitizing agent after
the unit has been cleaned and drained.
Rinse off the sanitizing agent thoroughly.

CAUTION

NEVER LEAVE A CHLORINE SANITIZING AGENT
IN  CONTACT  WITH  STAINLESS  STEEL  FOR
MORE THAN 30 MINUTES. LONGER CONTACT
CAN CAUSE CORROSION.  

j) It is recommended that the unit be sanitized

before use. 

k) If there is difficulty removing mineral

deposits or a film left by hard water or food
residues, clean the kettle thoroughly and use
a deliming agent, such as Groen Delimer
Descaler (P/N 114800) or  LimeAway from
Eco-Lab Inc. in accordance with the
manufacturer's directions. Rinse and drain
the unit thoroughly before further use.

l) If especially difficult cleaning problems

persist, contact your cleaning product
supplier for assistance.

5.3.4  Safety Precautions

A stopcock will be fitted in the gas pipe supplying
the appliance.  The user must be familiar with its
location and operation to be able to be turn it off  in
an emergency. If there is a smell of gas, turn off the
gas, ventilate the area and call the gas supplier. Do
not search for gas leaks with naked flames.

5.3.5  Service-Periodic Maintenance

A Maintenance and Service Log is included in this
manual.  Each time maintenance is performed,
enter the date the work was done, what was done,
and who did it. Periodic inspection can minimize
equipment down time and increase the efficiency of
operation.  The following points should be checked
regularly:

a) The pressure/vacuum gauge should show a

vacuum of 20 to 30 inches when the kettle is
cold.  If  it does not, the unit needs servicing.

b) Jacket water level should be between gauge

glass marks. If not, the unit needs servicing.

c)

Keep electrical wiring in good condition.

Содержание TDH-20

Страница 1: ...GRAM FOR First Choice Group Blakeney Way Kingswood Lakeside Cannock Staffs WS11 8LD TEL 01543 577778 FAX 01543504141 Email enquires firstchoice cs co uk Web www firstchoice cs co uk Steam Jacketed Ket...

Страница 2: ...SM TDH CE Part Number 128418 INTERNATIONAL Model TDH CE Mark Steam Jacketed Kettle Self contained Stainless Steel Gas Heated Table Mounted Tilting KEEP THIS MANUAL WITH KETTLE DOCUMENTS OPERATORS AND...

Страница 3: ...HE USER USERS SHOULD BE CONVERSANT WITH THE APPROPRIATE PROVISIONS OF THE FIRE PRECAUTIONS ACT AND THE REQUIREMENTS OF THE GAS SAFETY REGULATIONS IN PARTICULAR THEY SHOULD BE AWARE OF THE NEED FOR REG...

Страница 4: ...Procedure 10 3 5 Removal of Control Panels 11 3 6 Removal of Spark Ignition Module 11 3 7 Removal of Low Water Level Control 11 3 8 Removal of Tilt Switch 11 3 9 Removal of Gas Control Valve 12 3 10...

Страница 5: ...vicing by a competent person to ensure the continued safe and efficient performance of the Appliance WARNING TO PREVENT SHOCKS ALL APPLIANCES WHETHER GAS OR ELECTRIC MUST BE EARTHED Upon completion of...

Страница 6: ...should be made in accordance with local and or national regulations applying at the time A competent installer must be employed Recommendations for ventilation for catering appliances are given in BS...

Страница 7: ...ater Supply Not applicable to these appliances 1 8 Injector Diameters Natural and Propane Gas Injector TDH 20 TDH 40 G20 Nat Gas 0 94 mm 1 09 mm No of Orifices 8 12 G25 Nat Gas 1 09 mm 1 19 mm No Of O...

Страница 8: ...2 5 Pre Commissioning Check a Prior to operation clean out kettle pan thoroughly using hot water and detergent Rinse pan thoroughly b Remove all literature and packing materials from the interior and...

Страница 9: ...ess Replace in reverse order 2 5 3 Checking Performance of Controls a Light the unit as described in Paragraph 2 5 1 Check that the controls produce a healthy spark from the electrode to the earthing...

Страница 10: ...cation frequency depends on operating conditions but should be performed at least once every six months A 2 grade LGI lithium grease is recommended Add grease through the Zerk fittings on the gear hou...

Страница 11: ...inlet d Hold the safety valve open while you pour to let air escape from the jacket Air introduced during filling must be removed to obtain efficient heating Paragraph 3 2 CAUTION TDH STEAM JACKETED...

Страница 12: ...screws securing spark ignition module e Withdraw spark ignition module from control cabinet f Replace in reverse order 3 7 Remove Low Water Level Control Relay Turn gas and electric mains off a Remove...

Страница 13: ...itch or reset button as required f Replace in reverse order 3 11 Remove Neons Turn gas and electric mains off a Remove control cabinet lid Paragraph 3 5 1 b Remove cabinet side panel Paragraph 3 5 2 c...

Страница 14: ...s and electric mains off a Remove panel from base of kettle by undoing the retaining screws b Disconnect the electrical leads from the water level sensor c Drain the kettle by tilting the kettle sligh...

Страница 15: ...djustment required Note After fitting ensure there is an adequate spark between the pilot shroud and the spark electrode Also ensure that the sensing electrode is positioned in the pilot flame 3 18 Re...

Страница 16: ...RIZED DISTRIBUTORS CAN CAUSE INJURY TO THE OPERATOR AND DAMAGE TO THE EQUIPMENT AND WILL VOID ALL WARRANTIES SYMPTOM WHO WHAT TO CHECK Kettle is hard to tilt Auth Service Rep Only a Gears for foreign...

Страница 17: ...2 78 mm and located in the pilot gas stream If not adjust or replace the pilot e Orifice and clean if necessary Pilot lights but main burner will not come on and the spark stays on Auth Service Rep O...

Страница 18: ...ations In particular the need for regular servicing by a competent person to ensure the continued safe and efficient performance of the Appliance WARNING TO PREVENT SHOCKS ALL APPLIANCES WHETHER GAS O...

Страница 19: ...gas control valve The gas supply shuts off automatically when the kettle is tilted Service connections are required for gas and 230 V single phase 50 Hz electricity Important Prior to operation clean...

Страница 20: ...to be topped up This will require a service call e Check the pressure gauge If the gauge does not show sufficient vacuum 20 to 30 below zero the jacket will require venting This will require a service...

Страница 21: ...pressure is decreased c Pop safety valve which will release steam if the jacket pressure exceeds 50 PSIG See detailed Instructions pertaining to Safety Valve installation and operation Paragraphs 3 2...

Страница 22: ...y 12 hours b Scrape and flush out large amounts of food residues Be careful not to scratch the kettle with metal implements c Prepare a hot solution of the detergent cleaning compound as instructed by...

Страница 23: ...in the unit thoroughly before further use l If especially difficult cleaning problems persist contact your cleaning product supplier for assistance 5 3 4 Safety Precautions A stopcock will be fitted i...

Страница 24: ...OM SM TDH CE 23 Parts List...

Страница 25: ...OM SM TDH CE 24 PULL TILT MODELS CRANK TILT MODELS Parts List...

Страница 26: ...aft 113057 x 29 Gasket Bottom Cover 007937 x x 10 Worm gear 3 4 bore 012026 x 30 Thermostat Adapter 107172 x x 11 Spacer Washer 084956 x 31 Screw Rd Hd 6 32 x 3 8 009697 x x 12 Hand wheel 012061 x 32...

Страница 27: ...OM SM TDH CE 26 Electrical Panel Assembly TDH 40 and TDH 20 CE Models Gas Valve and Piping Assembly TDH 20 and TDH 40 Natural and Propane Gas CE Models Parts List...

Страница 28: ...2 NPT x 2 long 005551 x x 10 Fuse Holder 077854 x x 8 Bushing Reducing 1 2 x 3 8 NPT 012355 x x 11 Screw rd hd 6 32 x 1 4 lg 018384 x x 9 Connector 3 8 MNPT x 1 4 Tube 054498 x x 12 Fuse Three Amp 25...

Страница 29: ...OM SM TDH CE 28...

Страница 30: ...__________ Serial m _______________________________ Location ________________________________ Date Purchased __________________________ Date Installed ___________________________ Purchase Order m ____...

Страница 31: ...omponents found to be defective during the warranty period IV This warranty does not cover boiler maintenance calibration or periodic adjustments as specified in operating instructions or manuals and...

Страница 32: ...1055 Mendell Davis Drive Jackson Mississippi 39212 Telephone 601 373 3903 FAX 601 373 9587 OM SM TDH CE INTERNATIONAL Part Number 128418 Revised October1999...

Отзывы: