Model G0833P (Mfd. Since 06/17)
-61-
Troubleshooting
Symptom
Possible Cause
Possible Solution
Machine does not
start, or power
supply
breaker
immediately trips
after startup.
1. Locking pin installed in switch.
2. Machine circuit breaker tripped.
3. Power supply circuit breaker tripped or fuse
blown.
4. Plug/receptacle at fault/wired incorrectly.
5. Motor wires connected incorrectly.
6. Wiring open/has high resistance.
7. START/STOP switch or circuit breaker at
fault.
8. Start capacitor at fault.
9. Motor at fault.
1. Remove locking pin from START button.
2. Reset circuit breaker on switch.
3. Ensure circuit is sized correctly and free of shorts.
Reset circuit breaker or replace fuse.
4. Test for good contacts; correct the wiring.
5. Correct motor wiring connections (
Page 76).
6. Check/fix broken, disconnected, or corroded wires.
7. Replace switch/circuit breaker.
8. Test/replace if faulty.
9. Test/repair/replace.
Machine stalls or is
underpowered.
1. Feed rate/cutting speed too fast.
2. Workpiece material unsuitable for machine.
3. Motor overheated; tripping machine circuit
breaker.
4. Blade dull or incorrect for type of cut.
5. Belt(s) slipping.
6. Motor wired incorrectly.
7. Pulleys slipping on shaft or misaligned.
8. Run capacitor at fault.
9. Motor bearings at fault.
10. Contactor not energized/has poor contacts.
11. Centrifugal switch at fault.
12. Motor at fault.
1. Decrease feed rate/cutting speed.
2. Only cut wood/ensure moisture is below 20%.
3. Clean motor/let cool, and reduce workload. Reset
breaker.
4. Use correct, sharp blade; reduce feed rate.
5. Tension/replace belt(s).
6. Wire motor correctly (
Page 76).
7. Tighten/replace loose pulley; ensure pulleys are
aligned (
Page 74)
8. Test/repair/replace.
9. Test/repair/replace.
10. Test all legs for power/replace if faulty.
11. Adjust/replace centrifugal switch if available.
12. Test/repair/replace.
Machine has
vibration or noisy
operation.
1. Motor or component loose.
2. Blade at fault.
3. Belt(s)/pulley(s) worn, loose, or misaligned.
4. Motor mount loose/broken.
5. Machine incorrectly mounted/resting on
floor.
6. Arbor pulley loose.
7. Motor fan rubbing on fan cover.
8. Arbor bearings at fault.
9. Motor bearings at fault.
1. Inspect/replace damaged bolts/nuts, and re-tighten
with thread-locking fluid.
2. Replace warped/bent blade; resharpen dull blade.
3. Inspect/replace belts with new matched set. Realign/
replace shaft, pulley, set screw, and key (
Page 74).
4. Tighten/replace.
5. Tighten mounting bolts; relocate/shim machine.
6. Retighten/replace arbor pulley.
7. Fix/replace fan cover; replace loose/damaged fan.
8. Replace arbor housing bearings; replace arbor.
9. Test by rotating shaft; grinding/loose shaft requires
bearing replacement.
Review the troubleshooting and procedures in this section if a problem develops with your machine. If
you need replacement parts or additional help with a procedure, call our Technical Support.
Note: Please
gather the serial number and manufacture date of your machine before calling.
SECTION 8: SERVICE
Содержание Polar Bear G0833P
Страница 92: ......