Model G0833P (Mfd. Since 06/17)
-15-
4. Use wire nuts to connect wires as indicated
in
Figure 7. Twist wire nuts onto their respec-
tive wires and wrap them with electrical tape
so they will not come loose.
5. Close and secure motor junction box.
6. Remove start/stop switch box from the switch
mounting plate.
7. Replace pre-installed 10-amp circuit breaker
(see
Figure 8) with a 20-amp circuit breaker
(part #P0833P224X),
then re-install START/
STOP switch.
Circuit
Breaker
Figure 8. Location of circuit breaker.
8. Install a 5-20 plug on power cord, according
to plug manufacturer's instructions.
— If plug manufacturer's instructions are not
available, NEMA standard 5-20 plug wiring
is provided on
Page 76.
Figure 7. Motor rewired to 115V.
Motor Rewired
for 115V
GND
Rewired for 110V
The voltage conversion MUST be performed by
an electrician or qualified service personnel.
The voltage conversion procedure consists of
rewiring the motor and installing the correct plug.
A wiring diagram is provided on
Page 76 for your
reference.
IMPORTANT: If the diagram included on the
motor conflicts with the one on
Page 76, the motor
may have changed since the manual was printed.
Use the diagram included on the motor instead.
Items Needed
Qty
•
Phillips Head Screwdriver #2 ..................... 1
•
Electrical Tape ............................ As Needed
•
Wire Cutters/Stripper .................................. 1
•
NEMA 5-20 Plug ......................................... 1
•
Circuit Breaker 20A (P0833P224X) ............ 1
Converting Voltage
to 115V
To convert Model G0833P to 115V:
1. DISCONNECT MACHINE FROM POWER!
2. Cut off existing 6-20 plug.
3. Open motor junction box, then loosen three
wire nuts indicated in
Figure 6.
Figure 6. Location of wire nuts to be loosened
on motor junction box.
110V/220V
MOTOR
Motor Prewired
for 230V
GND
Connect
Wires with
Nuts Here
Loosen
These
Wire
Nuts
Содержание Polar Bear G0833P
Страница 92: ......