To verify machine parameters:
1. Press MENU, then scroll to Machine Setup
on the controller and press OK.
2. Scroll to each parameter shown on this page
and press OK to verify.
— To change a parameter, press RUN/
PAUSE, then enter the new parameter.
Press OK to save.
Verifying Parameters
Machine parameters are essential to any operation.
If the parameters are wrong, the machine will not
produce accurate results, and damage to the
machine and workpiece may occur. The machine
parameters have been set at the factory, but they
can be changed or lost due to hardware, software,
or power issues. Consult this section to verify and
reset parameters.
Pulse Equivalent:
Unit Pulse Per MM
X Equival ................................................ 160.000
Y Equival ................................................ 160.000
Z Equival ................................................. 320.000
Table Size:
Unit mm
X Equival ................................................ 600.000
Y Equival ................................................ 900.000
Z Equival ................................................. 130.000
Home Setup:
Home Speed mm/sec
X Equival .............................................. 6000.000
Y Equival .............................................. 6000.000
Z Equival ............................................... 6000.000
Set Home Direction
X Equival .......................................................Neg
Y Equival .......................................................Neg
Z Equival ........................................................ Pos
Speed Limit:
Z Speed Limit MM/Min.
-Dir ........................................................ 3000.00
+Dir ........................................................ 1800.00
X Speed Limit MM/Min.
-Dir ........................................................ 4000.00
+Dir ........................................................ 4000.00
Y Speed Limit MM/Min.
-Dir ........................................................ 4000.00
+Dir ........................................................ 4000.00
Verify machine parameters before running
any operation whenever machine is pow-
ered ON. Parameters can be changed or
lost when power cycling occurs, and operat-
ing with incorrect parameters may result in
damage to machine or workpiece.