4
English
1.1 Safety information
1.1.1 Protecting against electric shock
• Disconnect the unit from mains supply before servicing it or performing any other action.
• Always ground/earth the unit electrically.
• Before connecting the unit to power supplies, verify that operating voltage and frequency are compatible.
• Do not handle the unit with wet hands or in the presence of water.
• Check regularly that the power supply cable is not damaged or crushed.
• Apply to a qualified technician for any regular maintenance action not described in this manual.
1.1.2 Installation
• Fix the unit with screws, hooks or any other support able to bear the weight of the unit itself.
• If the unit is fixed onto a suspended structure, this structure is supposed to bear at least ten times the weight of
all devices to be fixed.
• The unit installation actions must be performed by a qualified staff.
1.1.3 Protection against burns and fire
•
Suitable to be installed onto normally inflammable surfaces.
• If the projector is in a fixed position and the beams is directed towards a flammable surface, the unit should be
kept at a minimum of 1 mt. If the beam is directed to people or thing at a distance lower than 2 mt, please
turn the lamp immediately off.
• The unit is not to be installed in places where the ambient temperature exceeds 35° (95°F).
• The external temperature of the unit surface (front glass) can reach 80°C (176°F).
• The lamp is very hot during operations! Wait at least for 20 minutes before changing.
1.1.4 Protection against lamp explosion
• Please replace any lamp that may present any damage or deformation.
• During the lamp replacement always use adequate body and eye protection (see the lamp manufacturer
instruction)
1.1.5 Weather protection
The unit is classified as device with an IP65 weather protection rate.
1.1.6 Protection against UV radiation
• Never operate the fixture with missing or damaged lenses and / or cover.
•
Replace any damaged shields with original GRIVEN spare parts..
•
Do not stare directly into the light. Never look at an exposed lamp while it is lit.
1.3 Compliance
• Product in compliance with EN60598-1 EN60598-2-17.
• Product in compliance with 2002/95/CE (RoHS).
1.0 Introduction
Warning!
This unit is suitable for professional use only, not for domestic use.
Содержание GR0466
Страница 1: ...GOBOSTORM GR0466 Instruction manual...
Страница 2: ......