background image

 

TH-BANK8 

INSTRUCTION MANUAL

 

I.  Technical Specifications: 

 

Item Code: 

 

 

TH-BANK8 

Product Description:  

Bank Light 8 (also known as stage blinder) 

Voltage: 

   AC 

120V 

or 

230V, 

50-60HZ, 

 

 

 

 

 

 

Voltage dependant on how lamps are wired. 

Bulb/Lamp: 

 

 

DWE 120V/max 650W(8X) Screw Terminal 

Weight: 

   10.0 

kgs 

22 

lbs 

Size: 

    17.75"W 

31.9"H 

4"D 

Wiring: 

 

 

 

Requires internal wiring customization of lamps for voltage 

 

II.    Operational & Installation Instructions: 

 

1. 

Unpack the carton to check if there is damage or missing parts when you receive the unit, call the local dealer if 

anything is not in normal condition. 

2. 

The unit is supplied with four input PG11 cable glands. Internal and external wiring must be completed prior to using 

this fixture. DO NOT plug these in before completing desired wiring. Depending on your desired input voltage and lamp 

fixture pattern output, you must wire the lamps in series or parallel using 120v lamps. By putting two lamp in series, that 

circuit may operate at an input voltage of 240v. Use appropriate wiring to handle the current and heat necessary for proper 

operation. Multiple plug inputs are provided because at 120v, a normal circuit could not provide enough current to feed all 

the 650w lamps. Refer to a qualified electrician for advise or contact your dealer for assistance in wiring. 

3. 

Open each lamp cover to install lamp. Keep lamp clean while installing and tighten screw terminals. Never install 

lamps with power connected. Disconnect power before re-lamping and make sure lamps are cool before touching.   

4. 

Place the unit where there is efficient ventilation, away from any flammable and explosive materials. 

5. 

Check that the rated power corresponds to the main supply. 

                                                 

III.  Re-lamping: 

 

1. 

Disconnect from power supply and let cool down before re-lamping. 

2. 

Remove each safety lamp holding ring and replace burned out lamp. 

3. 

Restore the lamp holding safety ring cap. 

 

IV.  CAUTION:

 Carefully read and observe for proper and safe use. 

1.

 

Ambient temperature should not exceed 40

2.

 

Disconnect from the power supply before opening or replacement of any lamp. Please be sure the lamp is cool before 

replacement! 

3.

 

To avoid electrical shock, do not touch any live parts when the unit is activated. 

4.

 

Call professionals for maintenance, no spare parts are included with the unit. 

5.

 

Give the unit a break after 15 minutes of continuous use. 