![Greyline Instruments SLT 5.0 Скачать руководство пользователя страница 37](http://html.mh-extra.com/html/greyline-instruments/slt-5-0/slt-5-0_user-manual_2264665037.webp)
Page 37
SLT 5.0 Level and Flow Monitor
Optional Sensor PZ32TE
Maximum Range:
32 ft. (10 m)
Deadband (blanking):
Programmable, minimum 12” (305
mm)
Beam Angle:
8° at 3 DB
Temperature Compensation:
Automatic, continuous
Operating Frequency:
42 KHz
Exposed Materials:
Teflon
Operating Temperature:
-40° to 170°F (-40° to 76°C)
Operating Pressure:
20 psi (1.35 Bar) maximum
Mounting:
¾” NPT (Teflon isolation coupling
supplied)
Sensor Cable:
RG62AU coaxial, 25 ft. (7.6 m)
standard
Hazardous Rating:
with optional Intrinsic Safety Barrier:
CSA, Class I,II,III, Div. I,II, Groups
C,D,E,F,G,
Note: Max Range reduced to 25 ft
(7.6 m) with ISB option.
Optional PZ15
Maximum Range:
15 ft (4.57 m)
Minimum Range (Deadband):
8" (203.2 mm)
Operating Frequency:
92 KHz
Beam Angle:
8°
Operating Temperature:
-40° to 150° (-40° to
65°C)
Temperature Compensation:
Automatic, continuous
Max. Operating Pressure:
20 psi (1.35 bar)
Sensor Face:
PVC
Sensor Body:
PVC
Mounting:
¾" NPT
Cable Length:
25 ft. (7.6 m) continuous
RG62AU coaxial.
Optional 50 ft. (15 m)
continuous
Max. Cable Length:
500 ft. (152 m) RG62AU
coaxial (splice)
Hazardous Rating:
CSA rated Intrinsically
Safe Class I, Groups
C,D, Class II, Groups
E,F,G with Optional
Intrinsic Safety Barrier.
Содержание SLT 5.0
Страница 2: ...Note This page has been left blank intentionally ...
Страница 5: ...Page 5 SLT 5 0 Level and Flow Monitor CONNECTIONS ...
Страница 7: ...Page 7 SLT 5 0 Level and Flow Monitor CALIBRATION MENU ...
Страница 14: ...Page 14 SLT 5 0 Level and Flow Monitor CHANNEL SETUP ...
Страница 20: ...Page 20 SLT 5 0 Level and Flow Monitor SENSOR MOUNTING METHODS ...