 Operating Manual GMH 3451 

page 3 of 18 

 

 _____________________________________________________ 

_____________________________________________________________________________ 

 

1 General 

Note 

Read this document carefully and get used to the operation of the device before you use it. Keep this 
document within easy reach near the device for consulting in case of doubt. 

2 Safety 

2.1 Intended Use 

The device is designed for measuring conductivity, resistivity, salinity and TDS in fluids – using a 
permanently connected electrode (measuring cell).  

It is designed for the mobile use or the stationary operation in a controlled electromagnetic environment (lab). 

Personnel which starts up, operates and maintains the device has to have sufficient knowledge of the 
measuring procedure and the meaning of the resulting measured values, this manual delivers a valuable 
help for this. The instructions of the manual have to be understood, regarded and followed.  

To be sure that there´s no risk arising due to misinterpretation of measured values, the operator must have 
further knowledge in case of doubt - the user is liable for any harm/damage resulting from misinterpretation 
due to insufficient knowledge. 

The manufacturer will assume no liability or warranty in case of usage for other purpose than the intended 
one, ignoring this manual, operating by unqualified staff as well as unauthorized modifications to the device. 

2.2  Safety signs and symbols 

Warnings are labelled in this document with the followings signs: 
 

 

Caution! 

This symbol warns of imminent danger, death, serious injuries 

and significant damage to property at non-observance. 

 

Attention! 

This symbol warns of possible dangers or dangerous 

situations which can provoke damage to the device or environment at 
non-observance. 

 

Note! 

This symbol point out processes which can indirectly influence 

operation or provoke unforeseen reactions at non-observance.

 

2.3 Safety guidelines 

This device has been designed and tested in accordance with the safety regulations for electronic devices. 
However, its trouble-free operation and reliability cannot be guaranteed unless the standard safety measures 
and special safety advises given in this manual will be adhered to when using the device. 

1.  Trouble-free operation and reliability of the device can only be guaranteed if the device is not subjected to 

any other climatic conditions than those stated under "Specification". 
If the device is transported from a cold to a warm environment condensation may cause in a failure of the 
function. In such a case make sure the device temperature has adjusted to the ambient temperature 
before trying a new start-up. 

2.     

  If there is a risk whatsoever involved in running it, the device has to be switched off 

immediately and to be marked accordingly to avoid re-starting. 
Operator safety may be a risk if: 
- there is visible damage to the device 
- the device is not working as specified 
- the device has been stored under unsuitable conditions for a longer time. 
In case of doubt, please return device to manufacturer for repair or maintenance. 

3.  When connecting the device to other devices the connection has to be designed most thoroughly as 

internal connections in third-party devices (e.g. connection GND with protective earth) may lead to 
undesired voltage potentials that can lead to malfunctions or destroying of the GMH 5155 and the 
connected devices. 

Содержание GMH 3451

Страница 1: ...49 0 9402 9383 0 49 0 9402 9383 33 info greisinger de Please carefully read these instructions before use Please consider the safety instructions Please keep for future reference as of version 1 3 GMH...

Страница 2: ...6 ELECTRODES MEASURING CELLS 8 6 6 1 Design 8 6 6 2 Calibration Adjustment of measuring cells 8 6 7 TEMPERATURE COMPENSATION 8 6 7 1 Temperature compensation nLF according to EN 27888 8 6 7 2 Linear t...

Страница 3: ...ficant damage to property at non observance Attention This symbol warns of possible dangers or dangerous situations which can provoke damage to the device or environment at non observance Note This sy...

Страница 4: ...ion If and bAt is shown in the lower display the battery has been used up and needs to be replaced However the device will operate correctly for a certain time If bAt is shown in the upper display the...

Страница 5: ...shortly change over between measuring units only if InP SEt is selected press for 2 sec menu invoke configuration menu min max when taking measurements press shortly min or max value is displayed pre...

Страница 6: ...tached to a belt etc The device with pop up clip at position 90 can be set up on a table etc The device with pop up clip at position 180 can be suspended from a screw or the magnetic holder GMH 1300 D...

Страница 7: ...d solids measurement the filtrate dry residue is determined by means of the conductivity and a conversion factor C tdS Well suited for easy concentration measurements of e g salt solutions The determi...

Страница 8: ...t see chapter 15 Accuracy Check Adjustment Service 6 7 Temperature compensation The conductivity of aqueous solutions depends on its temperature The temperature dependency is strongly dependent on the...

Страница 9: ...Input Selection of measured variable Cond Conductivity rESi Resistivity tdS Total dissolved solids SAL Salinity SEt Change over measured variables by Set key TDS measurement conversion factor only if...

Страница 10: ...uld correspond to output 0 V e g for 0 0 S cm 0 0 S cm 400 mS cm Measuring value that should correspond to output 1 V e g for 100 0 mS cm Set Corr Measurement correction Zero point adjustment offset o...

Страница 11: ...be used The software also allows easy configuration and starting of the logger When the logger is activated Func Stor or Func CYCL the hold function is no more available the key store is solely used...

Страница 12: ...rding Press store for 2 seconds Start menu press again automatic recording is started Each storage process is signalled by shortly displaying St XXXX where XXXX is the number of the saved data set If...

Страница 13: ...es In case you want to develop your own software we offer a GMH3000 development package including A universally applicable Windows functions library GMH3000 DLL with documentation that can be used by...

Страница 14: ...re different from default settings the device will shortly display Corr after turned on Default setting for offset and scale are off 0 0 i e inputs are not changed Zero point correction Displayed valu...

Страница 15: ...orrect pH calibration The device provides the following functions to help with this 12 1 Calibration interval C Int You can input the interval after which the device reminds you to recalibrate The int...

Страница 16: ...rer for repair Err 1 Measured value above allowable range Check pressure not within sensor range measuring value to high Sensor defective Return to manufacturer for repair Err 2 Measured value below a...

Страница 17: ...at housing or sensor may be a risk for persons or environment Use an adequate transport package for reshipment especially for fully functional devices Please make sure that the device is protected in...

Страница 18: ...l symbols Additional functions Min max hold Adjustment Calibration Cell correction manually or automatically via selectable reference solution Data logger Real time clock Cyclic 10000 data sets cycle...

Отзывы: