background image

  7. GENERAL MAINTENANCE INFORMATION

WHEN SHOULD I SERVICE  

MY UNIT?

SERVICE AND ACCESSORIES

Detailed maintenance information is 
located on the front decal on motor plate.

PRE-FILTER AND CARBON FILTER

Replace filters every 3 to 6 months or as 
needed. 

HEPA FILTER

Replace filter every 2 to 5 years or as 
needed. Check regularly to maintain 
maximum performance from your 

 

HVAC   system.  
For replacement filters, contact your local 
HVAC contractor.

INSIDE THE UNIT

Once a year or as needed, clean the 
interior of the unit (Wall and Motor Plate) 
with a mild and non-abrasive soap. It is 
recommended to use products that are 
environmentally friendly.

WARNING :

 ALWAYS UNPLUG UNIT  

 

         BEFORE SERVICING

4.1 CHANGING FILTERS

After opening the unit’s door, grasp both edges of filter and pull with 
equal force to slide out the filter.

4.2 CLEANING

Once a year or as needed, clean the interior of the unit (Wall and motor 
plates) using mild non-abrasive soap and water. It is recommended to 
use products that are environmentally friendly.

4.3 TROUBLESHOOTING

4.3 ELECTRICAL WIRING DIAGRAM

TROUBLESHOOTING

Unit does not operate

Unit operates only on one speed.

Unit vibrates

SUGGESTIONS

• Is power cord fully inserted in the 

unit’s connector?

• Is outlet powered?
• Is door interlock switch operating?

Possible loose wire inside electrical box, 
contact your local contractor.
Check for excessive dust build up or 
missing balancing weight on the impeller 
wheel.

Door 

Interlock 

Brown 

Blue 

Black 

2.5uf 

7.5uf 

Speed 

Selection 

Greentek

50 Kanalflakt Way., Bouctouche, NB  E4S 3M5

1-888-724-5211    Fax 1-866-426-7430

www.greentek.ca

Содержание HS 3.0

Страница 1: ...MODEL HS 3 0 Product of Greentek Greentek reserves the rights to modify a product without prior notice whether in price design color or codes in order to offer at all times quality products that are...

Страница 2: ...in a polarized outlet only one way Do not use filtration system for outdoor application Do not pull or twist power cord when disconnecting it from the ventilation system Grasp the plug firmly not the...

Страница 3: ...m Round Port Openings Installation type Plenum Wall or Floor Mounted Electrical Supply 120 VAC 60 Hz Power Consumption 134 W Certification CCSA US Air flow data 220 300 CF M Installation requires kit...

Страница 4: ...LLAR SYSTEM Installation Using kit no 463085 the Whole House HEPA Filtration system can be convert ed to use 8 inch round collars for appli cation requiring ducting The kit includes two 8 inch round c...

Страница 5: ...is supplied with the unit If not available a 120VAC outlet needs to be supplied NOTE Refer to Section 4 for details on how to remove the unit s door and filters STEP BY STEP INSTALLATION Steps involv...

Страница 6: ...ail able please call an electrical contractor to have one installed MAKE SURE TO INSTALL FILTER ACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filters and it is...

Страница 7: ...to the filters and speed selection switch Opening the latch on the right side of the unit will permit the door to swing open A safety door interlock switch cuts the power to the motors for your safety...

Страница 8: ...LTERS After opening the unit s door grasp both edges of filter and pull with equal force to slide out the filter 4 2 CLEANING Once a year or as needed clean the interior of the unit Wall and motor pla...

Отзывы: