background image

3

RETURN AIR PLENUM INSTALLATION

BOX CONTENT

Includes:
• Whole House HS 3.0 
• Power cord, 5 FT 
• Plenum seal, 7.5 FT 
• Screws, (16) 8 x 32 x 1/2” 
• Template

Front View

Side View - Clearance

Back View

SPECIFICATIONS

  1. UNPACKING AND INSPECTION

  2. TECHNICAL DATA

Model HS 3.0

Filtration Stage 1 & 2  Prefilter/ Carbon (461007)

Filtration Stage 3 

HEPA filter (461005)

Weight 

28 lbs (12.7 kg)

PlenumMount  

16” x 3.5” 

Port Openings 

 (406mm x89mm)

Collar Mount  

8” (203mm) Round* 

Port Openings 

Installation type 

Plenum,Wall* or  

 Floor*Mounted

Electrical Supply 

120 VAC @ 60 Hz

Power Consumption  134 W

Certification 

CCSA US

Air flow data 

220-300 CF.M.

* Installation requires kit No.463085

17”

(432 mm)

13”

(330 mm)

22”

(559 mm)

11”

(294.5 mm)

12”

(305 mm)

17”

(432 mm)

22”

(559 mm)

RETURN AIR PLENUM INSTALLATION AND STAND ALONE INSTALLATIONS

*

 

With Collar Mount Kit

Front View

Side View - Clearance

Side View

17”

(432 mm)

13”

(330 mm)

22”

(559 mm)

11”

(294.5 mm)

12”

(305 mm)

17”

(432 mm)

13”

(330 mm)

22”

(559 mm)

IMPORTANT: 
463046 -

 Pre+carbon filter kit is a 

universal filter and replaces 461007 

463048 -

 HEPA Filter kit is a universal 

filter and replaces 461005

Содержание HS 3.0

Страница 1: ...MODEL HS 3 0 Product of Greentek Greentek reserves the rights to modify a product without prior notice whether in price design color or codes in order to offer at all times quality products that are...

Страница 2: ...in a polarized outlet only one way Do not use filtration system for outdoor application Do not pull or twist power cord when disconnecting it from the ventilation system Grasp the plug firmly not the...

Страница 3: ...m Round Port Openings Installation type Plenum Wall or Floor Mounted Electrical Supply 120 VAC 60 Hz Power Consumption 134 W Certification CCSA US Air flow data 220 300 CF M Installation requires kit...

Страница 4: ...LLAR SYSTEM Installation Using kit no 463085 the Whole House HEPA Filtration system can be convert ed to use 8 inch round collars for appli cation requiring ducting The kit includes two 8 inch round c...

Страница 5: ...is supplied with the unit If not available a 120VAC outlet needs to be supplied NOTE Refer to Section 4 for details on how to remove the unit s door and filters STEP BY STEP INSTALLATION Steps involv...

Страница 6: ...ail able please call an electrical contractor to have one installed MAKE SURE TO INSTALL FILTER ACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filters and it is...

Страница 7: ...to the filters and speed selection switch Opening the latch on the right side of the unit will permit the door to swing open A safety door interlock switch cuts the power to the motors for your safety...

Страница 8: ...LTERS After opening the unit s door grasp both edges of filter and pull with equal force to slide out the filter 4 2 CLEANING Once a year or as needed clean the interior of the unit Wall and motor pla...