  4. TYPE OF INSTALLATION: STAND ALONE

  5. INSTALLATING THE UNIT: STEP BY STEP

ATTIC INSTALLATION

Ideal for homes without a 
forced air heating / cooling 
system. Allows for air filtra-
tion and circulation through-
out the home.
HEPA system must be operated continuously whenev-
er a part or all the system is located in an unconditioned 
space to avoid condensation in the ductwork below freezing  
(0°C, 32°F).

BASEMENT INSTALLATION

Ducting will usually consist 
of one return with grille from 
one side of the home, and one 
supply with grille at the oppo-
site end of the home. 

TOOLS REQUIRED

• Phillips #2 or Robertson #1 

screwdriver

• 3/32” drill bit
• Tin snips or metal shear
• Power Drill

LOCATION

 

Return side connections is to be installed 
after the last branch on the return air 
plenum and minimum 2 linear ft distance 
from furnace. 
A 5-ft power cord is supplied with the unit. 
If not available a 120VAC outlet needs to 
be supplied.

NOTE

: Refer to Section 4 for details on 

how to  remove the unit’s door and filters

STEP BY STEP INSTALLATION

Steps involved in the preparation of the plenum mount system are as followed:

Step 1

  Preparing return air plenum

Find a location that satisfies both service and maintenance requirements and proceed 
to cut holes as illustrated below.

Tape template to return air plenum. Cut opening with metal shears, predrill for the 
securing screws and remove template.

Step 2

  Preparing ducting flairs

Remove the door and filters and proceed to cut the insulation as illustrated below.

SUM

ME

R/

ÉTÉ

 

H

I

V

E

R

 

-

2

0

° C

 

       TEMPERA

TUR

MAINTENANCE

CYCLES / HOUR
20 / 40

30/30

RANGE
OFF

NORMAL

REDUCED

INTERN

CONT

RECIRC

MODE

Cut the insulation along 
the inside edge of both in-
let and outlet ports to re-
move the insulation from 
the port openings.

One cut permits the clean 
removal of the insulation 
piece.

The unit should look like 
this when the foam piece 
is remvouved.

Содержание HS 3.0

Страница 1: ...MODEL HS 3 0 Product of Greentek Greentek reserves the rights to modify a product without prior notice whether in price design color or codes in order to offer at all times quality products that are...

Страница 2: ...in a polarized outlet only one way Do not use filtration system for outdoor application Do not pull or twist power cord when disconnecting it from the ventilation system Grasp the plug firmly not the...

Страница 3: ...m Round Port Openings Installation type Plenum Wall or Floor Mounted Electrical Supply 120 VAC 60 Hz Power Consumption 134 W Certification CCSA US Air flow data 220 300 CF M Installation requires kit...

Страница 4: ...LLAR SYSTEM Installation Using kit no 463085 the Whole House HEPA Filtration system can be convert ed to use 8 inch round collars for appli cation requiring ducting The kit includes two 8 inch round c...

Страница 5: ...is supplied with the unit If not available a 120VAC outlet needs to be supplied NOTE Refer to Section 4 for details on how to remove the unit s door and filters STEP BY STEP INSTALLATION Steps involv...

Страница 6: ...ail able please call an electrical contractor to have one installed MAKE SURE TO INSTALL FILTER ACCORDING TO AIR FLOW DIRECTION FOR MAXIMUM PERFORMANCE Check for this symbol on each filters and it is...

Страница 7: ...to the filters and speed selection switch Opening the latch on the right side of the unit will permit the door to swing open A safety door interlock switch cuts the power to the motors for your safety...

Страница 8: ...LTERS After opening the unit s door grasp both edges of filter and pull with equal force to slide out the filter 4 2 CLEANING Once a year or as needed clean the interior of the unit Wall and motor pla...

Отзывы: