GreenTech RD1830 Series Скачать руководство пользователя страница 9

       

 

 

 

 

Intelligent Radar Level

 

Transmitter

 

Programming Menu

-

RD1830 series

 

 

 

Greentech, Korea 

 

www.greentechkor.com                                                                                                                                                    E-mail: [email protected] 

3. Diagnose:

 

When LCD indicates main menu, press button SELECTION to move the 
diagnosis of the arrow, LCD indicates as follows: 

BASIC SETTING   
INDICATION   
DIAGNOSE   
SERVICE   
INFORMATION 

The function of diagnose can be used for testing the working conditions of 
the instrument and other parts and debugging the system. Press button 
OK to enter the function of diagnose. 
 

 

3.1. Peak 
measurement:

 

Peak indication is the indication of the distance peak during the 
measurement. This parameter can be deleted with the reset under item 
4.4 of service menu. LCD indicates as follows: 

MEASUREMENT PEAK                                3.1 
MINIMUM DISTANCE VALUE             

   

    0.000 m (d)   

MAXIMUM DISTANCE VALUE                    2.109 m (d) 

 
 

 

3.2. Measurement 
mode:

 

When LCD indicates the menu number 3.1, press button SELECTION to 
enter the next diagnose mode. LCD indicates as follows: 

MEASUREMENT MODE                                3.2 
MEASUREMENT RELIABILITY:           

     

  20 dB   

SENSOR MODE:                                 

   

 

 

    OK 

 
 

 

3.3. Curve 
selection:

 

When LCD indicates the menu number 3.2, press button SELECTION to 
enter graph indication mode. LCD indicates as follows: 

CURVE SELECTION                                      3.3 
ECHO GRAPH 

When need to select other curves, press button OK to enter curve 
selection menu. LCD indicates as follows: 

CURVE SELECTION                                      3.3 
ECHO GRAPH 
FALSE ECHO GRAPH   
OUTPUT TREND CURVE 

Press button SELECTION to move the arrow to the point which is required 
to be indicated along the curve, press button OK for confirmation. 
 
 

 

3.4. ECHO GRAPH:

 

When LCD indicates the menu number 3.3, press button SELECTION to 
make LCD indicate the selected curve. The function of curve zoom can be 
used to amplify the curve along the axes of time and amplitude so that it to 
be read clearly. When LCD indicates graph, press button OK to enter 
curve zoom editing menu. LCD indicates as follows: 

CURVE ZOOM                                                3.4 
ZOOM ALONG AXIS X   
ZOOM ALONG AXIX Y   
NO ZOOM 

Press button SELECTION to move the arrow for selecting zoom direction 
or no zoom, press button OK 
for confirmation. When select zoom along axis X, press button 
SELECTION to move the start point to the place where it is needed, press 
button OK for confirmation. Press button SELECTION again to move the 
end point to the place where it is needed, press button OK for 
confirmation. At the time, the area selected is amplified up to the whole 
screen. Press button “ESC” to exit the curve indication. 

Содержание RD1830 Series

Страница 1: ...ing digits of edited parameters Indicating the content of the selected parameter Note hereinafter the button is called as KEY SELECTION for easy understanding Amending values of parameters Selecting m...

Страница 2: ...ress the OK button to enter programming state display programming main menu Each parameter editor to finish with OK button confirmation otherwise the editor is invalid When done editing press the esc...

Страница 3: ...relationship together with low position adjustment When LCD indicates the menu number 1 1 press button SELECTION enter high position adjustment LCD indicates as follows HIGH POSITION ADJUSTMENT 1 2 1...

Страница 4: ...u of surface wave LCD indicates as follows SURFACE WAVE 1 3 3 NO Press button OK again and enter the menu of surface wave LCD indicates as follows SURFACE WAVE 1 3 3 YES NO 1 3 3 Solid big stack angle...

Страница 5: ...1 3 6 NO Press button OK enter guided wave pipe measurement selecting menu LCD indicates as follows GUIDED WAVE PIPE MEASUREMENT 1 3 6 YES NO Press button SELECTION and select YES and press button OK...

Страница 6: ...ter When LCD indicates the menu number 1 5 press button SELECTION to enter output mapping editing menu LCD indicates as follows OUTPUT MAPPING 1 6 LINEARITY Press button OK to enter parameter selectio...

Страница 7: ...eters then press button OK for confirmation 1 10 Dead zone Dead zone When there is a fixed obstacle close to the propagator it interferes the measurement when the maximum medium level cannot be up to...

Страница 8: ...nstrument indicates measured distance Press button Ok to enter editing mode LCD indicates as follows INDICATING CONTENT 2 1 NO WORKING MAPPING PERCENTAGE DISTANCE CALIBRATED VALUE MEDIUM LEVEL CURRENT...

Страница 9: ...er graph indication mode LCD indicates as follows CURVE SELECTION 3 3 ECHO GRAPH When need to select other curves press button OK to enter curve selection menu LCD indicates as follows CURVE SELECTION...

Страница 10: ...TANCE Press button SELECTION to select current output mapping mode press button OK for confirming entering the set menu After setting the figures press button OK for confirmation At this time the set...

Страница 11: ...s button OK for confirmation LCD indicates waiting and then the instrument enters the state of false echo setting When it finishes LCD goes back to false echo setting menu Note the difference between...

Страница 12: ...dium level corresponds to 4mA high medium level corresponds to 20mA 20 4mA means that low medium level corresponds to 20mA high medium level corresponds to 4mA When LCD indicates current output select...

Страница 13: ...ction to set the instrument into multiple working mode When LCD indicates language menu number 4 5 press button SELECTION to enter working mode menu LCD indicates as follows HART WORKING MODE 4 6 STAN...

Страница 14: ...nally press button OK for confirmation Echo graph indication steps are as follows Method 1 1 Press button OK to enter the programming state LCD indicates program main menu 2 Select submenu press butto...

Страница 15: ...15 Intelligent Radar Level Transmitter Programming Menu RD1830 series Greentech Korea www greentechkor com E mail info greentechkor com Attached Diagram...

Страница 16: ...16 Intelligent Radar Level Transmitter Programming Menu RD1830 series Greentech Korea www greentechkor com E mail info greentechkor com...

Отзывы: