6
Intelligent Radar Level
Transmitter
Programming Menu
-
RD1830 series
Greentech, Korea
www.greentechkor.com E-mail: [email protected]
Note:
Please carefully choose “MICRO DK”. It is not suitable for the most
of measurement. After selecting MICRO DK, according to the situation of
echoes, the instrument will adopt using direct echo method or bottom
reflection method to get the measurement result.
1.4 Damping time:
Damping time: When LCD indicates the menu number 1.3, press button
SELECTION, enter damping time setting menu, LCD indicates as follows:
DAMPING TIME: 1.4
6S
Press button OK, enter parameter edit mode. Press button “+” to set the
figures. Press button SELECTION to select the figure digit to be edited.
Then press button OK for confirmation.
1.5. Signal
threshold:
signal threshold is used for the basic line for setting output linearity. When
LCD indicates
the menu number 1.4, press key SELECTION to enter output mapping
editing menu, LCD indicates as follows:
SIGNAL THRESHOLD 1.5
25mV
Press button OK and enter editing mode, press button “+” to set figures.
Press button OK for confirmation after editing.
1.6. Output
mapping:
Output mapping: output mapping is used for selection between
nonlinearity output mapping and linearity mapping set from a host
computer. When LCD indicates the menu number 1.5, press button
SELECTION to enter output mapping editing menu. LCD indicates as
follows:
OUTPUT MAPPING 1.6
LINEARITY
Press button OK to enter parameter selection mode. Press button
SELECTION to select linearity or other selectable mapping modes, for
example, linearity, horn, etc. Press button OK for confirmation after editing.
When select linearity output mapping, it will be used for selecting different
units.
1.7. Calibration
unit:
Calibration unit: When LCD indicates the menu number 1.6, press button
SELECTION to enter calibration unit setting menu. LCD indicates as
follows:
CALIBRATION UNIT 1.7
HEIGHT m
Press button OK to enter parameter selection mode, then press button
SELECTION for confirmation, and select the corresponding unit, press
button OK for confirmation. When select linearity output mapping, it will be
used for determining concrete mapping relationship.
1.8. Calibration:
Calibration: When LCD indicates the menu number 1.7, press button
SELECTION to enter calibration setting menu. LCD indicates as follows:
CALIBRATION 1.8
0%= 0.00 m
100%= 0.00 m
Press button OK, the area of parameter become black, press button
SELECTION to set the decimal point, press button OK for confirmation.
The parameters area corresponds to 0% become black. Press button
SELECTION and button “+” for setting parameters.
Then press button OK for confirmation. For setting the values
corresponding to 100%, the steps and methods are the same.