3.5. Simulation:
Simulation is to simulate output 4-20mA, which is used to if output of
instrument is normal.
Meanwhile, it can be used for system debugging. When LCD indicates the
menu number 3.4, press button
SELECTION to enter simulation mode. LCD indicates as follows:
SIMULATION 3.5
START SIMULATION
Press button OK for confirm simulation, LCD indicates as follows:
SIMULATION 3.5
PERCENTAGE
CURRENT
DISTANCE
Press button SELECTION to select current output mapping mode, press
button OK for confirming entering the set menu. After setting the figures,
press button OK for confirmation. At this time, the set value of the current
output corresponds to the current value.
Note: Three alternative menus illustration percentage: output current
according to the given percentage. For example, 100% corresponds to
20mA, 0% corresponds to 4mA. Current: output current according to the
given current value. For example, 16.6mA corresponds to 16.6mA.
Distance: output current according to distance value (this relationship
between this value and the current value can be determined by 1.1. low
position adjustment, 1.2. high position adjustment and 1.5. output
mapping).