14
Intelligent Radar Level
Transmitter
Programming Menu
-
RD1830 series
Greentech, Korea
www.greentechkor.com E-mail: [email protected]
Press button OK, LCD indicates as follows:
COPY SENSOR DATA 4.7
COPY FROM SENSOR
COPY TO SENSOR
Press button SELECTION to select the menu you need, and press button
OK for confirmation and perform the function.
4.8. Password:
Password is used for the safety of the parameters. Once the function is
actuated, you have to input the password every time when you want to
change a parameter.
When the right passwords are input, the protection function will be
cancelled. Then you can modify the parameters.
When LCD indicates menu number 4.7, press button SELECTION to enter
the password function. LCD indicates as follows:
PASSWORD ACTUATE IT? 4.8
Or
PASSWORD CANCELL IT? 4.8
Press button OK to actuate password function and set password or cancel
it.
4.9. Distance
offset:
Distance offset is used for modifying the measurement error, which is the
difference between actual distance and the indicated distance.
When LCD indicates menu number 4.8, press button SELECTION to enter
distance offset menu. LCD indicates as follows:
DISTANCE OFFSET 4.9
+0.000m (d)
Press button OK for confirmation, then press button “+” and button
SELECTION to set offset. Finally press button OK for confirmation.
Echo graph indication steps are as follows:
Method 1:
1. Press button OK to enter the programming state, LCD indicates program main menu
2. Select submenu: press button SELECTION to move the arrow to the diagnosis submenu 3, the
number “3” is indicated at the right upper corner of the screen.
3. Press button OK for confirmation. Enter the diagnosis submenu 3.1 for indicating measurement
peak: minimum distance and maximum distance.
4. Press button SELECTION to next programmable item for indicating measurement state 3.2:
measurement reliability, sensor state:
5. Press button SELECTION again, enter selecting curve submenu 3.3.
6. Press button OK, enter parameters selection menu:
7. Press button
SELECTION to move the arrow to select “ECHO GRAPH”, press button OK for
confirmation.
8. Press button SELECTION for indicating ECHO GRAPH 3.4.
9. Press button OK to enter curve zoom menu.
10. Press button SELECTION to zoom at axis X, press button OK for confirmation.
11.
Press button SELECTION to move “the start point” to the place or point you need, press button
ESC for confirmation.
12.
Press button SELECTION to move “the end point” to the place or point you need, press button OK
for confirmation. At this time, the selected curve has been magnified up to the whole screen.
13. Press button ESC continuously until the instrument go back to operation state.
Method 2:
Under main menu, press button ESC directly.
This is shortcut for indicating the ECHO GRAPH.