DC Voltage M easu re ment
The DC Voltage r anges ar e: 400.0mV, 4.000 V, 40.00 V, 400.0 V and 1000V. To measu re DC voltage, conne ct the Met er
as follows:
7. Insert the red test lead into the
HzV
Ω
te r min al and the black test le ad into th e
C O M
ter minal.
8. Set the rotary switch to Hz
V
; DC me asureme nt is default or press the
B LUE
button to select DC measu rement
mode .
9. Connect the test le ads a cross with the obj ect b eing me asured.
The me asured valu e shows on the display.
Note
l
In e ach range , the Meter has an input i mped anc e of 10M
Ω
. This loading e ffect can caus e measureme nt er rors in
high impedance circuits. I f the ci rcuit i mped ance is less than or equal to 10k
Ω
, the error is negligible (0.1% or
less).
l
When DC voltage measur e ment has been co mpleted , disconne ct the connection betw een the testing leads and the
circuit unde r t est.