Model MSCF Modular Small Cabinet Fan

®

Hanging Bracket

Part No. 710774

Drawing No. 85537

Hanging Bracket

Part No. 710774

Drawing No. 85537

Bridge Bracket

Part No. 711779

Drawing No. 89814

One required per assembly

Bridge Bracket

Part No. 711779

Drawing No. 89814

One required per assembly

3/4 inch Flat Washer

One required per assembly

3/4 inch Flat Washer

One per assembly as needed

3/8-16x3/4 Spinlock Bolt

Two required per assembly

3/8-16x3/4 Spinlock Bolt

Two required per assembly

3.0 inch

3/8-16 Spinlock Nut

Two required per assembly

3/8-16 Spinlock Nut

Two required per assembly

HANGING ASSEMBLY

BASE ASSEMBLY

Hanging Bracket

Part No. 710774

Drawing No. 85537

Hanging Bracket

Part No. 710774

Drawing No. 85537

Bridge Bracket

Part No. 711779

Drawing No. 89814

One required per assembly

Bridge Bracket

Part No. 711779

Drawing No. 89814

One required per assembly

3/4 inch Flat Washer

One required per assembly

3/4 inch Flat Washer

One per assembly as needed

3/8-16x3/4 Spinlock Bolt

Two required per assembly

3/8-16x3/4 Spinlock Bolt

Two required per assembly

3.0 inch

3/8-16 Spinlock Nut

Two required per assembly

3/8-16 Spinlock Nut

Two required per assembly

HANGING ASSEMBLY

BASE ASSEMBLY

Mounting Instructions

Greenheck’s Modular Small Cabinet Fan (MSCF) 
should be lifted by the factory supplied lifting lugs 
(see Figure 1) or frame rails and a spreader bar 
(see Figure 2) to prevent damage from occurring to 
the equipment. Avoid twisting or uneven lifting of 
equipment. Do not lift equipment by coil connections 
or headers. The unit must remain upright during lifting. 
All access doors and panels must be closed during 
lifting to avoid damage.

Hanging Instructions

The MSCF should be hung by the factory supplied 
lifting lugs or field supplied frame rails as shown 
respectively in Figures 3 and 4. The number of 
hanging brackets used will be determined by the 
number of fan modules.

External Mounting Isolation

The MSCF is available with external neoprene or 
spring isolation options. When external isolation is 
selected, a bridge bracket will be provided to reduce 
installation time (see Figure 5).

Figure 4

Figure 5

Figure 3

Figure 1

Lifting lugs

Spreader Bar

Frame Rails

(by others)

Figure 2

Spreader Bar

Содержание MSCF-BI

Страница 1: ...ation and Maintenance Manual Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by obser...

Страница 2: ...are accounted for by referencing the bill of lading to ensure all items were received Inspect each crate for shipping damage before accepting delivery Notify the carrier if any damage is noticed The c...

Страница 3: ...Electric Heater 15 Maintenance Fan 16 Coil 16 Drain Pan 16 Reference Start Up Documentation 17 Maintenance Log 18 19 Warranty Backcover Unit Layout 1 Fan and Cabinet Section 2 Cooling Section Chilled...

Страница 4: ...3 0 inch 3 8 16 Spinlock Nut Two required per assembly 3 8 16 Spinlock Nut Two required per assembly HANGING ASSEMBLY BASE ASSEMBLY Mounting Instructions Greenheck s Modular Small Cabinet Fan MSCF sho...

Страница 5: ...4 Row HW Steam 15 6 75 18 5 18 5 6 75 6 75 18 5 6 75 9 5 18 5 19 38 2 5 3 5 43 20 6 75 18 5 18 5 6 75 6 75 18 5 6 75 9 5 18 5 19 38 2 5 3 5 43 25 6 75 21 18 5 6 75 6 75 21 6 75 9 5 18 5 23 38 2 5 3 5...

Страница 6: ...ertical Quantity Face Area Sloped Quantity Face Area 15 9x18 2 1 8 12x12 1 2 5 12x24 1 20 12x12 1 2 5 16x16 1 3 4 12x24 1 16x20 1 25 14x18 2 3 0 16x20 2 3 8 30 16x16 1 3 4 12x24 1 5 3 16x20 1 24x24 1...

Страница 7: ...15 50 9 38 3 188 1 375 4 0 26 0 85 8 6 62 12 75 9 38 3 188 1 375 4 0 26 0 All dimensions are in inches NOTE With airflow from left to right the fluid enters the coil from the bottom connection Inlet...

Страница 8: ...2 50 24 5 21 0 10 12 14 1 38 1 63 65 6 7 50 24 5 26 0 10 12 14 1 38 1 63 85 8 6 62 24 5 26 0 10 12 14 1 38 1 63 All dimensions are in inches Unit Size Face Area A B C L M N P 4 Row 6 Row 8 Row All Al...

Страница 9: ...should be capped off cap Unit Size Face Area A B C D E F G 4 Row 6 8 Row 4 Row 6 Row 8 Row 30 3 2 38 24 5 18 5 9 25 11 0 7 88 8 50 8 5 7 00 12 0 45 4 5 50 24 5 18 5 9 25 11 0 7 88 8 50 8 5 7 00 12 5 5...

Страница 10: ...rage and Fan RPM All access doors must be installed Measure and record the input voltage and motor amperage s To measure the fan RPM the blower door will need to be removed Minimize measurement time b...

Страница 11: ...ductwork Repair Elbows or other obstructions may restrict fan outlet Correct or improve ductwork Belt slippage Adjust belt tension Unit running backwards Correct as shown in System Start Up section S...

Страница 12: ...independently of the coils Undue stress should not be applied at the connection to coil headers 2 The condensate drain pipe should be sized adequately to ensure the condensate drains properly See Drai...

Страница 13: ...are recommended for low pressure steam On high pressure systems bucket traps are normally recommended The thermostatic traps should be used only for air venting 3 Bucket traps are recommended for use...

Страница 14: ...he requirements and practices described below are based on the National Electric Code NEC and The Space Heating Standard of the Underwriters Laboratories Inc UL Although UL requirements are uniform th...

Страница 15: ...with the thermostat set to 70 F the heater will be off with a temperature sensing above 70 F As the temperature varies the steps turn on and off to hold the setpoint discharge temperature The colder...

Страница 16: ...n air Occasionally oil and dust may accumulate on the wheel causing imbalance When this occurs the wheel and housing should be cleaned to assure smooth and safe operation Inspect fan impeller and hous...

Страница 17: ...rated enough to prevent freeze up NOTE Carefully read instructions for mixing antifreeze solution used Some products will have a higher freezing point in their natural state than when mixed with water...

Страница 18: ...___________________________ _________________________________________________ _________________________________________________ Date___________________ Time______________ AM PM Notes _________________...

Страница 19: ...___________________________ _________________________________________________ _________________________________________________ Date___________________ Time______________ AM PM Notes _________________...

Страница 20: ...or installation costs As a result of our commitment to continuous improvement Greenheck reserves the right to change specifications without notice Phone 715 359 6171 Fax 715 355 2399 E mail gfcinfo g...

Отзывы: