Model MSCF Modular Small Cabinet Fan

®

Dimensional Data

Filter Sizes and Quantity

Unit 

Size

A

B

C

D

E

F

G

Unit 

Width

Inlet

Outlet

w/o 

Filter

w/ 

Filter 12 in. 24 in. Vertical Sloped

Hot Water

1 & 2 Row

4 Row HW 

& Steam

Height Width Height Width

15

11

24.5 12.75 24.5

12.75

24.5

12.75

15.5

24.5

25

11

38

9

36

4

6.75

20

14

24.5 12.75 24.5

12.75

24.5

12.75

15.5

24.5

25

14

38

12

36

6.5

6.75

25

16

27

12.75 24.5

12.75

27

12.75

15.5

24.5

29

16

38

14

36

8

8.5

30

18.5

31

12.75 24.5

12.75

31

12.75

15.5

24.5

32

18.5

38

16.5

36

9

9

45

18.5

32

12.75 24.5

12.75

32

12.75

15.5

24.5

32

18.5

50

16.5

48

9

10

50

21

32

12.75 24.5

12.75

32

12.75

15.5

24.5

38

21

50

19

48

10.25

10

65

26

38

12.75 24.5

12.75

38

12.75

15.5

24.5

42

26

50

24

48

12

12.75

85

26

38

12.75 24.5

12.75

38

12.75

15.5

24.5

42

26

62

24

60

12

15

*See CAPS for electric heating dimensions.
All dimensions are in inches.

24 

PLENUM

12 

PLENUM

CHILLED 

WATER 

COIL

HEATING 

COIL

VERTICAL

FILTER

FAN

MIXING BOX

w/DAMPER

24 

PLENUM

12 

PLENUM

CHILLED 

WATER 

COIL

HEATING 

COIL

VERTICAL

FILTER

FAN

MIXING BOX

w/DAMPER

 

Mixing 

Plenum 

Filter 

*Heating 

Cooling / Combo 

Fan

 

Box 

 

 

 

Coil

A

B

C

D

E

F

G

Unit 

Size

Vertical

Quantity

Face

Area

Sloped

Quantity

Face

Area

15

9x18

2

1.8

12x12

1

2.5

12x24

1

20

12x12

1

2.5

16x16

1

3.4

12x24

1

16x20

1

25

14x18

2

3.0

16x20

2

3.8

30

16x16

1

3.4

12x24

1

5.3

16x20

1

24x24

1

45

16x24

2

4.8

24x24

2

7.2

50

18x24

2

5.4

24x24

2

7.2

65

24x24

2

7.2

24x24

4

14.4

85

12x24

1

8.9

12x24

2

17.8

24x24

2

24x24

4

Weights

Unit 

Size

A

B

C

**D

**E

F  (FC)

F  (BI)

w/o 

Filter

w/ 

Filter 12 in. 24 in. Vertical Sloped

Hot Water

1 & 2 Row

4 Row HW 

& Steam

CW/DX

Fan

Max 

Motor Total

Fan

Max 

Motor Total

15

80

107

31

57

34

61

61

86

145

94

50

144

-

-

-

20

95

126

36

68

41

72

72

101

171

111

50

161

-

-

-

25

105

140

40

75

45

80

80

112

190

130

60

190

168

60

228

30

118

157

45

84

50

90

88

123

209

150

75

225

182

75

257

45

132

176

50

94

55

100

99

138

234

194

75

269

239

100

339

50

151

202

58

108

64

115

113

159

269

253

100

353

279

100

379

65

197

263

75

141

77

150

136

190

323

328

125

453

333

100

433

85

226

302

85

170

90

175

140

196

350

360

140

500

375

100

475

All weights are approximated. Motor weights may very depending on enclosure type and horsepower. 

**Weight information for hot water, steam, chilled water and DX coils is wet weight.

*See CAPS for electric heat dimensions.

Содержание MSCF-BI

Страница 1: ...ation and Maintenance Manual Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by obser...

Страница 2: ...are accounted for by referencing the bill of lading to ensure all items were received Inspect each crate for shipping damage before accepting delivery Notify the carrier if any damage is noticed The c...

Страница 3: ...Electric Heater 15 Maintenance Fan 16 Coil 16 Drain Pan 16 Reference Start Up Documentation 17 Maintenance Log 18 19 Warranty Backcover Unit Layout 1 Fan and Cabinet Section 2 Cooling Section Chilled...

Страница 4: ...3 0 inch 3 8 16 Spinlock Nut Two required per assembly 3 8 16 Spinlock Nut Two required per assembly HANGING ASSEMBLY BASE ASSEMBLY Mounting Instructions Greenheck s Modular Small Cabinet Fan MSCF sho...

Страница 5: ...4 Row HW Steam 15 6 75 18 5 18 5 6 75 6 75 18 5 6 75 9 5 18 5 19 38 2 5 3 5 43 20 6 75 18 5 18 5 6 75 6 75 18 5 6 75 9 5 18 5 19 38 2 5 3 5 43 25 6 75 21 18 5 6 75 6 75 21 6 75 9 5 18 5 23 38 2 5 3 5...

Страница 6: ...ertical Quantity Face Area Sloped Quantity Face Area 15 9x18 2 1 8 12x12 1 2 5 12x24 1 20 12x12 1 2 5 16x16 1 3 4 12x24 1 16x20 1 25 14x18 2 3 0 16x20 2 3 8 30 16x16 1 3 4 12x24 1 5 3 16x20 1 24x24 1...

Страница 7: ...15 50 9 38 3 188 1 375 4 0 26 0 85 8 6 62 12 75 9 38 3 188 1 375 4 0 26 0 All dimensions are in inches NOTE With airflow from left to right the fluid enters the coil from the bottom connection Inlet...

Страница 8: ...2 50 24 5 21 0 10 12 14 1 38 1 63 65 6 7 50 24 5 26 0 10 12 14 1 38 1 63 85 8 6 62 24 5 26 0 10 12 14 1 38 1 63 All dimensions are in inches Unit Size Face Area A B C L M N P 4 Row 6 Row 8 Row All Al...

Страница 9: ...should be capped off cap Unit Size Face Area A B C D E F G 4 Row 6 8 Row 4 Row 6 Row 8 Row 30 3 2 38 24 5 18 5 9 25 11 0 7 88 8 50 8 5 7 00 12 0 45 4 5 50 24 5 18 5 9 25 11 0 7 88 8 50 8 5 7 00 12 5 5...

Страница 10: ...rage and Fan RPM All access doors must be installed Measure and record the input voltage and motor amperage s To measure the fan RPM the blower door will need to be removed Minimize measurement time b...

Страница 11: ...ductwork Repair Elbows or other obstructions may restrict fan outlet Correct or improve ductwork Belt slippage Adjust belt tension Unit running backwards Correct as shown in System Start Up section S...

Страница 12: ...independently of the coils Undue stress should not be applied at the connection to coil headers 2 The condensate drain pipe should be sized adequately to ensure the condensate drains properly See Drai...

Страница 13: ...are recommended for low pressure steam On high pressure systems bucket traps are normally recommended The thermostatic traps should be used only for air venting 3 Bucket traps are recommended for use...

Страница 14: ...he requirements and practices described below are based on the National Electric Code NEC and The Space Heating Standard of the Underwriters Laboratories Inc UL Although UL requirements are uniform th...

Страница 15: ...with the thermostat set to 70 F the heater will be off with a temperature sensing above 70 F As the temperature varies the steps turn on and off to hold the setpoint discharge temperature The colder...

Страница 16: ...n air Occasionally oil and dust may accumulate on the wheel causing imbalance When this occurs the wheel and housing should be cleaned to assure smooth and safe operation Inspect fan impeller and hous...

Страница 17: ...rated enough to prevent freeze up NOTE Carefully read instructions for mixing antifreeze solution used Some products will have a higher freezing point in their natural state than when mixed with water...

Страница 18: ...___________________________ _________________________________________________ _________________________________________________ Date___________________ Time______________ AM PM Notes _________________...

Страница 19: ...___________________________ _________________________________________________ _________________________________________________ Date___________________ Time______________ AM PM Notes _________________...

Страница 20: ...or installation costs As a result of our commitment to continuous improvement Greenheck reserves the right to change specifications without notice Phone 715 359 6171 Fax 715 355 2399 E mail gfcinfo g...

Отзывы: