Part No.

6001

2.4 MHz Nebulizer Board

6002

UPC Tank - Model#579R3 304SS with welds, stand brackets, top flange w/ PEMS and bottom hole
w/PE...

6003

Gasket for UPC Tank -

6004

Polypropylene Float Switch

6005

2-Way NC Stainless Stl Sol.Valve

6006

2-Way NO Stainless Stl. Sol.Valve

6007

Wall Metal Enclosure (20x20x12)

6008

Terminal connector blocks

6009

Terminal Connector End Blocks

6010

Jumpers - 2 Pole

6011

120VAC to 48VAC Transformer. Rated for

6012

120VAC to 24VAC Transformer. Rated for 250VA. Open.

6013

Hobo Data Logger

6014

Hobo Data Logger - 2 channels

6015

50 GPD RO System

6016

Redington Hour Meter -

6017

Control Panel for the RAH 2000 & 3000

6019

1.65 MHz PC Board

6020

Relay 24VAC, 15 Amp, Dpdt, 8 terminal

6021

Relay Socket - 8 terminal

6024

Lexan Clear Poly Sheet .22"thk, 24"x24" sheet

6025

PLC Controller for Humidity

6026

Humidity Sensor - Duct HMD50U

6027

Humidity Sensor - Wall HMW50U

6028

Humidity Switch / simple controller

6029

Humidity Sensor - Duct 10

6030

Nema 1 Control Panel 12x12z6

6031

Gen Purpose Relay 24VAC 10Amp

6032

Screw 18-8 SS Pan Head Phillips Machine Screw 8

6033

Nut 18-8 SS Machine Screw Hex Nut. 8

6034

Washer - EPDM Rubber cushioning and sealing washer #8 screw size, .150 ID, 5/16 OD, .062 thick, ...

6035

Screw 18-8 Pan Head Phillips Machine Screw 8

6036

Nat.Rubber Sheet - 12" x 24" x 1/4"

6037

EPDM O Ring size: 4.5" OD

6038

15 Amp Littlefuse

6039

Idec Pilot Lite - Red - 24VAC

6040

Switch - 2 pos., lited - red 120V

6041

Circuit Breaker - 6 Amp 120V

6043

Idec Pilot Lite - Green -

6045

Idec Double Pole Relay

6046

Idec Double Pole Socket

6047

Idec Single Pole Relay -

6048

Idec Single Pole Socket

6050

EMI/RFI Fan Guard

PARTS LIST

Item Description

2.4 MHz Nebulizer Board

Model#579R3 304SS with welds, stand brackets, top flange w/ PEMS and bottom hole

Model#:579R3

Polypropylene Float Switch

Way NC Stainless Stl Sol.Valve

Way NO Stainless Stl. Sol.Valve

Wall Metal Enclosure (20x20x12)

Terminal connector blocks

Terminal Connector End Blocks

120VAC to 48VAC Transformer. Rated for 500VA. Open.

120VAC to 24VAC Transformer. Rated for 250VA. Open.

2 channels

- 24V

Control Panel for the RAH 2000 & 3000

Relay 24VAC, 15 Amp, Dpdt, 8 terminal

8 terminal

Lexan Clear Poly Sheet .22"thk, 24"x24" sheet

PLC Controller for Humidity

Duct HMD50U

Wall HMW50U

Humidity Switch / simple controller

Duct 10-35VDC input required. 0 - 10 VDC output.

Nema 1 Control Panel 12x12z6

Gen Purpose Relay 24VAC 10Amp

8 SS Pan Head Phillips Machine Screw 8-32 Trhread, 1/2" Length, Pack of 100

8 SS Machine Screw Hex Nut. 8-32, 5/16 width 100 per pack

EPDM Rubber cushioning and sealing washer #8 screw size, .150 ID, 5/16 OD, .062 thick, ...

8 Pan Head Phillips Machine Screw 8-32, 3/4" long, 100 per pack

12" x 24" x 1/4"

EPDM O Ring size: 4.5" OD

24VAC

red 120V

6 Amp 120V

24VAC

Idec Double Pole Relay - 24V

Idec Double Pole Socket

- 24VAC

Idec Single Pole Socket

20

Sales

Price

31.00

Model#579R3 304SS with welds, stand brackets, top flange w/ PEMS and bottom hole

144.00

10.00

28.52

35.60

66.36

332.00

0.94

1.40

0.64

89.00

64.80

250.00

240.00

258.00

54.52

1,350.00

27.28

16.26

11.24

69.44

160.00

250.00

270.00

80.00

148.00

170.00

32.00

32 Trhread, 1/2" Length, Pack of 100

0.00

0.00

EPDM Rubber cushioning and sealing washer #8 screw size, .150 ID, 5/16 OD, .062 thick, ...

0.00

0.00

0.00

25.00

19.75

25.00

52.00

36.00

25.00

13.40

8.46

12.60

7.00

10.00

Содержание RAH-SAU series

Страница 1: ...INSTALLATION AND OPERATION FOR VS 7 14 INSTALLATION AND OPERATION FOR RAH SAU Series 1 INSTALLATION AND OPERATION...

Страница 2: ...eference of the End User or Installer The following rules should be followed Place the Control Panel in a place where the outlet fog will not impinge on any surfaces Make sure to verify the air patter...

Страница 3: ...vide humidifiers Utilize a t connector provided and taped to the RO system metal frame to hook up the product water blue line to the storage tank Locate the 2 5 gallon storage bladder proximity to the...

Страница 4: ...Generator panel at the appropriately labeled locations on the terminals Refer to the Wiring Diagram provided with your unit for proper landing locations and line sizes Shielded control wire is recomme...

Страница 5: ...ed to a drain Turning the System On go to the control panel and make sure the panel on off switch is off open up the control panel and make sure the circuit breaker CB is off if CB is showing green th...

Страница 6: ...ith the system it should become active and show figures on it s display The should correspond to both the actual humidity level and the target set point humidity level Make sure their respective readi...

Страница 7: ...turned off and verify that the Humidifier turns off as well as air flow stops b With the AC System back on if possible locate the HiLimit switch and lower its setting to as low as it can go The switc...

Страница 8: ...xcessive continuous run time when humidifier is undersized or the space really needs more humidifiers but the customer elected not to furnish and install them If your model has a timer delay relay go...

Страница 9: ...ure that the comes on Verify that the air flow switch has closed after properly sensing that air is moving in the duct Verify that the HiLimit switch circuit is closed Check the Wet Switch and verify...

Страница 10: ...on when there is a call for humidification and not just when there is a call for heat There is a dry contact relay in the panel for exactly this purpose Contact the Installer to verify that he utilize...

Страница 11: ...g sure all the UPC discs that should be running are indeed doing so You may do this by observing the operation with a flash light and peering through the plastic lid or taking the lid off see above in...

Страница 12: ...12...

Страница 13: ...13...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...120V 1PH Power On R 96 VA 7 6 UPC TANK 3 2 WET SWITCH 9 40 VA 10 WIRING FOR RAH SAU LAB UNIT WITH VECTOR CONTROLLER G Fog On Fill SV 2 11 A 17B Low Water CR3 NC WET SWITCH R WS 12B CR3 CR4 FLOAT SWITC...

Страница 21: ...Idec Single Pole Relay 6048 Idec Single Pole Socket 6050 EMI RFI Fan Guard PARTS LIST Item Description 2 4 MHz Nebulizer Board Model 579R3 304SS with welds stand brackets top flange w PEMS and bottom...

Страница 22: ...y or Factory Representative for current pricing Fan Guard for 4 69 Fan Bulkhead Conn 1 4T x 1 8MPT Brass Part B 400 11 2 clear w paper back in square ft units 10 Amp fuse 12 32 dia time delay 250 VAC...

Отзывы: