Set up General Purpose In- and Outputs 

In the GP input/output menu you can set up the GPIO of this 4-wire port to interface with 
and trigger external communication systems. Each 4-wire port has a 9-pin sub D connector 
available with 2 inputs and 2 outputs.  

In x 

à

 

Set up one of the two inputs.  

Func   

à

 

Set up the function that is triggered by this input 

 

Talk  

à

 

Set up this input to trigger A talk.  

 

Call  

à

 

Set up this input to trigger a Call 

 

Cue  

à

 

Set up this input to Acknowledge or send an Attention, Hold  

 

 

or GO  

Option  

à

 

Set up on which channel this trigger is active. 

 

Func: Talk 

à

 

Either Answer the current active channels or select one  

  

 

 

specific channel.  

 

Func: Call 

à

 

Select the channel to call  

 

Func: Cue 

à

 

 Select which cue signal to send 

 

 

 

Acknowledge 

à

Send an acknowledge to the incoming cue 

 

 

 

Send ATT Chn 

à

Send an attention to one specific channel 

 

 

 

Send Hold Chn 

à

Send a hold signal to one specific channel 

 

 

 

Send GO Chn 

à

Send a GO signal to one specific channel 

Normally 

à

 

Set up the NOT active state of this input. 

Out x 

à

 

Set up one of the two outputs  

Func   

à

 

Set up the function that will trigger this Output 

 

Active 

à

 

An active channel will activate this output  

 

Call  

à

 

A call will activate this output 

 

Cue Receive 

à

 

Set up an output to be active when a Cue is received. 

 

Talk  

à

 

A local active talk will activate the output 

Option  

à

 

Set up on which channel this trigger is active. 

 

Func: Active 

à

 

Either Any channel or select a specific channel 

 

Func: Call 

à

 Either Any channel or select a specific channel 

 

Func: Cue Rec 

à

 

 Select which cue signal will trigger the output 

 

 

 

Hold     

à

 

Output is active when a Hold is active 

 

 

 

Hold Blink 

à

 Output is blinking when a Hold is active 

 

 

 

Att 

   

à

 Output is active when an Attention is active 

 

 

 

Att Blink 

à

 Output is blinking when an Attention is active 

 

 

 

GO 

   

à

 

Output is active when a GO is active 

 

 

 

Go Blink  

à

 Output is blinking when a GO is active 

 

 

 

Hold /Att Blink 

à

 Output is active when a Hold is active and 

 

 

 

   

   

blinking when an Attention is Active 

 

 

 

Hold Blink /Att  

à

 Output is blinking when a Hold is active and 

 

 

 

   

   

active when an Attentions active 

 

 

 

Hold /GO 

à

 Output is active when a Hold or GO is active 

 

 

 

Att / GO  

à

 Output is active when an Attention or GO is 

Содержание Quad 4-wire

Страница 1: ...Quad 4 wire Quick Start Guide...

Страница 2: ...al audio systems And connect up to 4 General purpose Audio line in outs This is ideal for purposes like program audio and announcements or complete user based engines with 32 channels and program audi...

Страница 3: ...low To Set up a 4 Wire port first select the mode to use Select a port and scroll down to Set User Mode 4 wire Port x Set User Mode Line in out Set up this port as General Purpose Input and Output thi...

Страница 4: ...x Gain becomes gain MaxGain Set the maximum gain of the input signal range is from 12 to 28 dB Threshold Set the gate function for this input The threshold is the level required for the input signal t...

Страница 5: ...this channel Momentary talk is enabled as long as a corresponding trigger is active Latch talk is toggled between enabled or disabled when a trigger becomes active Latch Momentary A combination of la...

Страница 6: ...s active range is from 0 dB to 24 dB and MUTE option Audio In Out Output Set the output level of the Audio Output Range is MUTE 42 to 6 dB LoopBack Set the ratio of audio feed back from the input back...

Страница 7: ...Chn Send a GO signal to one specific channel Normally Set up the NOT active state of this input Out x Set up one of the two outputs Func Set up the function that will trigger this Output Active An act...

Страница 8: ...pinout Pin 1 5v Capable off sourcing 200mA Pin 2 Input 1 Switch to ground to activate input 1 Pin 3 Input 2 Switch to ground to activate input 1 Pin 4 Output 1 High side of open collector capable of 5...

Страница 9: ...Normal the port does not reply to a incoming call Auto answer the port automatically replies with a Hold to a call Ignore the port ignores incoming calls Set up the connection type of a 4 wire port C...

Страница 10: ...the Internal Green GO network Dynamic Select the connection mode ON Use a dynamic IP If an DHCP server is on the network this will supply an IP address to the device If there is no DHCP server the de...

Страница 11: ...current config of the Quad 4 wire SN xxx Serial number of the Quad 4 wire 4 wire 4a61 Firmware information 4 wire 4a61 Firmware version Nov 16 2018 Date of firmware build 09 32 09 Time of firmware bu...

Страница 12: ...instructions Do not insert any objects through the ventilation slots of the unit as these could come in contact with live parts or could cause short circuits This could cause electric shock and or fir...

Страница 13: ...uad 4 wire Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive 2014 35...

Отзывы: