3.Installation

3-2 Movement

1)Because the gravity center of the unit is not in the middle, when you move the machine, please 

beware of the drumping.

2) Please do not hold the air inlet, or it will be deformed.

3) In the movement, please don’t touch the fan blade by hand or other things in order to prevent 

from the damage on the fan blade.

4)Please don’t lean it more than 45°C or lie it down.

5) Please try to use the auxiliary equipment, such as the forklift or crane to prevent the body injury 

caused by the overweight in the movement of the big models.

 

Warning

Determine the feasible moving path.

Please try to move the unit under the condition of the original

Install the accessories according to the requirements.

3-3 Installation

The installation should be done by the qualified dealer or professional technicians.

If the installation is improper, it may cause the water leak, current leak or accidents such as fire.

The installation bearing surface should be flat and can support the weight of the unit.

Please install the unit firmly by using the MB expansion valve to fix it on the stand and antivibration

rubber pads should be used to prevent the abnormal vibration and noise.

Please try to remove the barrier around the unit, otherwise the air circulation range will be too

small and affect the performance.

If the unit is installed in the basement, indoor or in the other closed space, good air circulation

between the unit and outdoor should be ensured.

If the unit is installed at the seaside or in the high place where there is strong wind, to make sure

the normal operation of the fan blade, it must be installed against the wall. If necessary please

use the baffle.

In the place where there is strong wind, please make sure the air outlet of the unit and the strong

wind are the same direction, in order to prevent the strong wind blow to the indoor unit and

affects the performance. If the wind direction can’t be ensured, please put baffle in front of wind.

 

 

Attention

The installation of the unit should comply with the user manual.

When the unit is moved to another place, the movement and installation should be

done by the professionals.

If the user installs the unit on their own, we’ll not be responsible for the accidents such

Содержание ANTEK AIR MAGNA 100

Страница 1: ...EEN ENERGY SYSTEMS AIR TO WATER HEAT PUMP DC INVERTER INSTALLATION AND MAINTENANCE MANUAL The piping connection should be installed according to the local legal laws and regulations as well as the pro...

Страница 2: ...SYSTEMS 2 1 Safe precautions 2 Structure 3 Installation 4 User instruction 5 Trial operation 6 Unit operation and performance 7 Maintenance and trouble shooting 8 Wiring diagram 9 WIFI function CONTE...

Страница 3: ...grounding is not reliable If you are not sure if the grounding is reliable please let the professional to check Please carefully read the safety precautions and notes about the machine before using i...

Страница 4: ...he accidents we ll not take the responsibility Attention The household power supply circuit to comply with relevant standards The power circuit should be equipped with leakage protector Check whether...

Страница 5: ...30 960 1030 1030 1110 H 803 810 803 1335 1250 T 380 370 380 380 450 L H T 1 Wind net 2 Wiring cover 3 Maintenance panel 4 Water outlet 5 Water inlet The photo in this manual is only for explanations p...

Страница 6: ...rnal wall meanwhile please waterproof measures should be done well There is sufficient space for installation and maintenance There is no barrier in front of the heat pump air outlet and strong wind c...

Страница 7: ...nit Please install the unit firmly by using the MB expansion valve to fix it on the stand and antivibration rubber pads should be used to prevent the abnormal vibration and noise Please try to remove...

Страница 8: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 8 3 Installation 3 4 The space of installation and maintenance...

Страница 9: ...ion of the water circuit system In order to make sure the protection on the unit when the system has no water do not bridge the water flow switch casually 7 Auto vent valve should be installed in the...

Страница 10: ...f happen and the water is not timely drained from the water circuit system then cause the damage on the unit and crack of the water system our company will not take the responsibility of the maintenan...

Страница 11: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 11 a Installation for only heating 3 Installation 3 8 Installation diagram b Installation for only hot water...

Страница 12: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 12 c Installation for hot water heating 3 Installation 3 8 Installation diagram...

Страница 13: ...nel will be locked automatically if there is no key operation within 60s and icon is displayed on the screen Press on off key for 3s to unlock it 4 2 1 On off key In unlock status press On off key to...

Страница 14: ...arameter values Combine the function key to query and set various parameters In the main interface press the key and key to set the temperature of the current mode In the temperature setting interface...

Страница 15: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 15 4 User instruction...

Страница 16: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 16 4 User instruction...

Страница 17: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 17 4 User instruction...

Страница 18: ...NA 100 GREEN ENERGY SYSTEMS 18 4 User instruction 4 3 2 Run parameters query table 4 2 In the main interface long press the key for 3 seconds to enter to check the run parameters As shown in the table...

Страница 19: ...setting In the main interface press the timing key for 3 seconds to enter the current clock setting interface In the current clock interface press the timing key once and the digits of the hour part w...

Страница 20: ...the current clock setting and return to the main interface In the current clock setting interface if there is no key operation for 60 seconds confirm the current clock setting value and return to the...

Страница 21: ...After setting the minutes for timing power on press the timing button again to enter the hour setting of timing power off the setting method is the same as above After setting the scheduled shutdown...

Страница 22: ...d after the buzzer beeps once 4 3 6 Forced defrost In the power on state press and hold the key and the function key for 3 seconds to enter the forced defrost 4 3 7 Parameters reset In the main interf...

Страница 23: ...are normal connect the power supply and start the unit During the trial operation check the following items 1 If the unit working performance is normal if it can normally produce the demanded heating...

Страница 24: ...mode and result in the water circuit freezing and damage on the unit If the unit will not be used for a long time please make sure the water circuit system is completely drained before cutting off th...

Страница 25: ...4 33 5 91 7 42 COP A 7 W55 1 88 1 91 1 87 1 73 1 82 Max water temp C 60 Rated water temp C 55 water flow m3 h 1 0 1 5 1 9 2 6 3 4 pressure drop Kpa 18 22 24 28 31 Net weight kg 72 90 96 124 190 Noise...

Страница 26: ...ting 7 1 Fault code table table 8 1 The unit will stop automatically if any fault happens during the operation meanwhile the fault code will display on the controller screen Please contact the service...

Страница 27: ...is prepared to be put in use again after a period of leaving unused please check the air inlet and air outlet to see if there is any blockage If there is blockage please clean up immediately 1 Before...

Страница 28: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 28 8 Wiring diagram...

Страница 29: ...or Android Enter the URL in the browser http d 3appstore com phx9 you will find Multi Machine app download and install The following instructions are based on the IOS system 9 2 User registration Clic...

Страница 30: ...te of intelligent network distribution and the icon will flash for 3 minutes Click the Confirm button on your phone Enter the WIFI password and press the Next button Press OK button the app start to f...

Страница 31: ...MAGNA 100 GREEN ENERGY SYSTEMS 31 9 WIFI function 9 4 App user guide Open the app click on the device name Enter the app control interface see the description for the name of each part of the interfa...

Страница 32: ...4 2 Set water temperature Drag the big dot on the temperature circle with your finger to adjust the set water temperature 9 4 3 Operation mode selection Press the M button You can call out the operati...

Страница 33: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 33 Note...

Страница 34: ...EK Green Energy Systems A DIVISION OF ANTEK INDUSTRIAL GROUP B ro und Lager Am Wienerweg 8 A 2403 Scharndorf E Mail info antek at www ANTEK GreenEnergy com www ANTEK IndustrialGroup com www ANTEK BM c...