background image

AIR MAGNA 100

GREEN ENERGY SYSTEMS

4

I. Safety Precautions

 

Warning

Requirements for the installation environment

The installation location must be ventilated, waterproof, sun-proof, and requires a convenient 

powersupply, water supply and drainage channels. 

Customer‘s electrical environment must be in accordance with local electrical safety regulations. 

The power supply specifications conform to the requirements of the local rating. There must be 

reliable grounding, leakage protector and give the machine power supply directly by the 

leakage switch wiring way.

The wall or stand must meet the bearing requirements The installation, maintenance and 

renovation must be done by the designated dealer and professionals.

If the operator does not have relevant professional knowledge and authorization, but install and 

repair to result in the damage on furniture and decoration, injury or electric shock, and even 

serious accidents such as fire, we’ll not assume legal responsibility.

The requirement on installation accessories Please use the accessories in the packing according 

to the requirement, do not replace them with any other similar.

The purchased parts must be the designated model or specification, if the parts beyond the 

specified are used and result in the accidents, we’ll not take the responsibility.

 

 

Attention

The household power supply, circuit to comply with relevant standards

The power circuit should be equipped with leakage protector.

Check whether the socket is qualified, after the unit runs for half an hour, remove the plug, if the 

pin is hot, that means the plug has more than 50 °C and must be replaced by another qualified 

one.

The location of the power supply should be not less than 1.8 meters from the ground, and be 

water-proof well and far from children.

The power lines have no damage. If there is any damage, please contact the relevant dealer or

professional staff for replacement.

The unit should be installed firmly to run without vibration and the noise will not affect the 

neighbors.

Drainage piping can smoothly drain and will not lead to leakage or make the furniture wet.

The installation space is well ventilated, once there is refrigerant leakage, the gas will not gather, 

so there is no combustible gas leak near the installation location. If there is such risk, please 

change the installation environment, otherwise, it’s easy to cause poisoning, fire accident, etc.

Do not keep the unit in the humid environment or exposed to the rain, otherwise it’s easy to 

damage the unit.

If there is refrigerant leak during the installation, ventilation measures must be taken 

immediately. Otherwise, if the leaked refrigerant meets fire, such as heater, stove or electric 

cooker, etc., poisonous gas maybe produced.

Содержание ANTEK AIR MAGNA 100

Страница 1: ...EEN ENERGY SYSTEMS AIR TO WATER HEAT PUMP DC INVERTER INSTALLATION AND MAINTENANCE MANUAL The piping connection should be installed according to the local legal laws and regulations as well as the pro...

Страница 2: ...SYSTEMS 2 1 Safe precautions 2 Structure 3 Installation 4 User instruction 5 Trial operation 6 Unit operation and performance 7 Maintenance and trouble shooting 8 Wiring diagram 9 WIFI function CONTE...

Страница 3: ...grounding is not reliable If you are not sure if the grounding is reliable please let the professional to check Please carefully read the safety precautions and notes about the machine before using i...

Страница 4: ...he accidents we ll not take the responsibility Attention The household power supply circuit to comply with relevant standards The power circuit should be equipped with leakage protector Check whether...

Страница 5: ...30 960 1030 1030 1110 H 803 810 803 1335 1250 T 380 370 380 380 450 L H T 1 Wind net 2 Wiring cover 3 Maintenance panel 4 Water outlet 5 Water inlet The photo in this manual is only for explanations p...

Страница 6: ...rnal wall meanwhile please waterproof measures should be done well There is sufficient space for installation and maintenance There is no barrier in front of the heat pump air outlet and strong wind c...

Страница 7: ...nit Please install the unit firmly by using the MB expansion valve to fix it on the stand and antivibration rubber pads should be used to prevent the abnormal vibration and noise Please try to remove...

Страница 8: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 8 3 Installation 3 4 The space of installation and maintenance...

Страница 9: ...ion of the water circuit system In order to make sure the protection on the unit when the system has no water do not bridge the water flow switch casually 7 Auto vent valve should be installed in the...

Страница 10: ...f happen and the water is not timely drained from the water circuit system then cause the damage on the unit and crack of the water system our company will not take the responsibility of the maintenan...

Страница 11: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 11 a Installation for only heating 3 Installation 3 8 Installation diagram b Installation for only hot water...

Страница 12: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 12 c Installation for hot water heating 3 Installation 3 8 Installation diagram...

Страница 13: ...nel will be locked automatically if there is no key operation within 60s and icon is displayed on the screen Press on off key for 3s to unlock it 4 2 1 On off key In unlock status press On off key to...

Страница 14: ...arameter values Combine the function key to query and set various parameters In the main interface press the key and key to set the temperature of the current mode In the temperature setting interface...

Страница 15: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 15 4 User instruction...

Страница 16: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 16 4 User instruction...

Страница 17: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 17 4 User instruction...

Страница 18: ...NA 100 GREEN ENERGY SYSTEMS 18 4 User instruction 4 3 2 Run parameters query table 4 2 In the main interface long press the key for 3 seconds to enter to check the run parameters As shown in the table...

Страница 19: ...setting In the main interface press the timing key for 3 seconds to enter the current clock setting interface In the current clock interface press the timing key once and the digits of the hour part w...

Страница 20: ...the current clock setting and return to the main interface In the current clock setting interface if there is no key operation for 60 seconds confirm the current clock setting value and return to the...

Страница 21: ...After setting the minutes for timing power on press the timing button again to enter the hour setting of timing power off the setting method is the same as above After setting the scheduled shutdown...

Страница 22: ...d after the buzzer beeps once 4 3 6 Forced defrost In the power on state press and hold the key and the function key for 3 seconds to enter the forced defrost 4 3 7 Parameters reset In the main interf...

Страница 23: ...are normal connect the power supply and start the unit During the trial operation check the following items 1 If the unit working performance is normal if it can normally produce the demanded heating...

Страница 24: ...mode and result in the water circuit freezing and damage on the unit If the unit will not be used for a long time please make sure the water circuit system is completely drained before cutting off th...

Страница 25: ...4 33 5 91 7 42 COP A 7 W55 1 88 1 91 1 87 1 73 1 82 Max water temp C 60 Rated water temp C 55 water flow m3 h 1 0 1 5 1 9 2 6 3 4 pressure drop Kpa 18 22 24 28 31 Net weight kg 72 90 96 124 190 Noise...

Страница 26: ...ting 7 1 Fault code table table 8 1 The unit will stop automatically if any fault happens during the operation meanwhile the fault code will display on the controller screen Please contact the service...

Страница 27: ...is prepared to be put in use again after a period of leaving unused please check the air inlet and air outlet to see if there is any blockage If there is blockage please clean up immediately 1 Before...

Страница 28: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 28 8 Wiring diagram...

Страница 29: ...or Android Enter the URL in the browser http d 3appstore com phx9 you will find Multi Machine app download and install The following instructions are based on the IOS system 9 2 User registration Clic...

Страница 30: ...te of intelligent network distribution and the icon will flash for 3 minutes Click the Confirm button on your phone Enter the WIFI password and press the Next button Press OK button the app start to f...

Страница 31: ...MAGNA 100 GREEN ENERGY SYSTEMS 31 9 WIFI function 9 4 App user guide Open the app click on the device name Enter the app control interface see the description for the name of each part of the interfa...

Страница 32: ...4 2 Set water temperature Drag the big dot on the temperature circle with your finger to adjust the set water temperature 9 4 3 Operation mode selection Press the M button You can call out the operati...

Страница 33: ...AIR MAGNA 100 GREEN ENERGY SYSTEMS 33 Note...

Страница 34: ...EK Green Energy Systems A DIVISION OF ANTEK INDUSTRIAL GROUP B ro und Lager Am Wienerweg 8 A 2403 Scharndorf E Mail info antek at www ANTEK GreenEnergy com www ANTEK IndustrialGroup com www ANTEK BM c...

Отзывы: