15
Operation Data
Notes:
(1) Measure surface temperature of heat exchanger pipe around center of heat exchanger path U-Bend.
(2) Length of connecting tubing = 24.6 ft.
(3) P = Pressure PSI
T1 = Inlet and Outlet Temperature for Evaporator
T2 = Inlet and Outlet Temperature for Condenser
Product Introduction
Temperature Condition (
O
F)
Model
Pressure
(
PSI)
Heat Exchanger
Pipe Temperature
Indoor Fan
Mode
Outdoor Fan
Mode
Compressor
Speed
(rps)
Indoor
Outdoor
T1 (
O
F)
T2 (
O
F)
80.6/66.6
95/75.2
9K
135
57.2
98.6
Turbo
High
46
12K
152
59
98.6
Turbo
High
70
18/24K
131-160
46.4-51.8 to
51.6-57.2
167-181.4 to
98.6-118.4
Turbo
High
75
Cooling
Temperature Condition (
O
F)
Model
Pressure
(
PSI)
Heat Exchanger
Pipe Temperature
Indoor Fan
Mode
Outdoor Fan
Mode
Compressor
Speed
(rps)
Indoor
Outdoor
T1 (
O
F)
T2 (
O
F)
70/60
47/43
9K
401
113
41
Turbo
High
56
12K
308
107.6
41
Turbo
High
73
68/59
44.6/42.8
18/24K
319-348
167-181.4
98.6-113
33.8-37.4 to
35.6-42.8
Turbo
High
75
Heating
Содержание TERRA09HP230V1A
Страница 13: ...13 Product Introduction Operation Characteristic Curve ...
Страница 14: ...14 Product Introduction Capacity Variation Ratio According to Temperature ...
Страница 16: ...16 Noise Criteria Curve Tables Product Introduction ...
Страница 54: ...54 Electrical Schematics ...
Страница 135: ...135 Gree Electric Appliances Inc C 2014 Cat No DFS TERRA HP 2SM Version 2 0 ...