Malfunction
Name
Indoor Unit Display
Method
Outdoor Unit
Display Method
(repeated every 5
seconds)
o
= Off
n
= Illuminated
«
= Blink
A/C Status
Possible Causes
Indoor
Display Cool Indicator
15
Limit/decrease
frequency due
to overload
F6
Off 3S and
blink 6 times
n
o
«
«
All loads operate normally,
while operation frequency
for compressor is decreased.
Refer to the malfunction
analysis (overload, high
temperature resistant).
16
Decrease fre-
quency due to
overcurrent
F8
Off 3S and
blink 8 times
n
n
o
n
All loads operate normally,
while operation frequency
for compressor is decreased.
The input supply voltage is
too low; System pressure is
too high and overload
17
Decrease
frequency due
to high air dis-
charge
F9
Off 3S and
blink 9 times
n
n
o
o
All loads operate normally,
while operation frequency
for compressor is decreased.
Overload or temperature
is too high; Refrigerant is
insufficient; Malfunction
of electric expansion valve
(EKV)
18
Voltage for DC
bus-bar is too
high
PH
Off 3S and
blink 11 times
o
n
o
During cooling and drying
operation, compressor will
stop while indoor fan will
operate. During heating
operation, the complete unit
will stop operation.
1. Measure the voltage of
position L and N on wiring
board (XT), if the voltage
is high than 265VAC, turn
on the unit after the supply
voltage is increased to the
normal range; 2. If the AC
input is normal, measure
the voltage of electrolytic
capacitor C on control
panel (AP1), if its normal,
theres malfunction for the
circuit, please replace the
control panel (AP1)
19
Malfunction of
complete units
current detec-
tion
U5
Off 3S and
blink 13 times o
n
«
n
During cooling and drying
operation, compressor will
stop while indoor fan will
operate. During heating
operation, the complete unit
will stop operation.
Theres circuit malfunction
on outdoor units control
panel AP1, please replace
the outdoor units control
panel AP1.
Troubleshooting 18,000/24,000 btuh Units, cont.
Содержание TERRA09HP230V1A
Страница 13: ...13 Product Introduction Operation Characteristic Curve ...
Страница 14: ...14 Product Introduction Capacity Variation Ratio According to Temperature ...
Страница 16: ...16 Noise Criteria Curve Tables Product Introduction ...
Страница 54: ...54 Electrical Schematics ...
Страница 135: ...135 Gree Electric Appliances Inc C 2014 Cat No DFS TERRA HP 2SM Version 2 0 ...