108
Disassembly of Indoor Unit
18,000 btuh
Warning - Wait 10 minutes after power is disconnected before starting disassembly
.
Step 1.
Remove the indoor tube temperature sensor
Step 2.
Remove the screws holding the bonding
wire, then remove the wire
Step 3.
Remove the clamps holding the electrical
box cover to remove cover.
Step 4.
Remove all wiring terminals, remove all
screws holding the box, then remove the
sub-assembly.
7. Remove electrical box sub-assembly
Heat exchanger thermistor
Bonding wire
Screw
Electrical box cover
Sub-assembly
Screw
Содержание TERRA09HP230V1A
Страница 13: ...13 Product Introduction Operation Characteristic Curve ...
Страница 14: ...14 Product Introduction Capacity Variation Ratio According to Temperature ...
Страница 16: ...16 Noise Criteria Curve Tables Product Introduction ...
Страница 54: ...54 Electrical Schematics ...
Страница 135: ...135 Gree Electric Appliances Inc C 2014 Cat No DFS TERRA HP 2SM Version 2 0 ...