AIR-TO-WATER HEAT PUMP MAINTENANCE
156
Parts List
of GRS-CQ8.0Pd/Na-K(I) ,GRS-CQ10Pd/Na-K(I),GRS-CQ12Pd/Na-K(I),
GRS-CQ14Pd/Na-K(I) and GRS-CQ16Pd/Na-K(I)
No.
Name of part
Part code
Quantity
1
Front Panel Cover
01262866P
1
2 Front
Panel
1542808 1
3
Electric Box Cover
1422821
1
4 Electric
Box
Assy
1392864 1
00902811
①
1
5
Plate Heat Exchanger
00902812
②
1
6 Water
Manometer
49028003 1
7 Bottom
Cover
Plate
1262876 1
8
Outlet Gas Pipe Sub-Assy
4322857 1
9
Inlet Gas Pipe Sub-Assy
4322859 1
10
Inlet Water Pipe Sub-Assy
4362891 1
11 Filter
7412808 1
12
Outlet Water Pipe Sub-Assy
4362888 1
13
Flow Switch Sub-Assy
45028062 1
14 Display
Board
30293301 1
15 Expansion
Drum
7422804 1
16 Water
Pump
43138221 1
17
Outlet Water Pipe Sub-Assy
4362917 1
18 Electric
Heater
32102802 1
19 Chassis
Sub-Assy
01192819P 1
20
Top Cover Plate
1262875 1
21 Relief
Valve
7382814 1
22
Connecting Pipe Sub-Assy
5032851 1
23
Auto Air Outlet Valve
7108208 1
24
Inlet Water Pipe Sub-Assy
4362893 1
25 Sensor
Sub-Assy
39008051 1
26
Terminal Board(4 bit)
42011051 1
27
Terminal Board(8 bit)
4201120401 1
28 AC
Contactor
44010245
3
29 Main
Board
30223311 1
30
Terminal Board(20 bit)
42011254 1
31 Transformer
4311027001 1
Note
:
①
Only is part of GRS-CQ8.0Pd/Na-K(I) and GRS-CQ10Pd/Na-K(I) Model.
②
Only is part of GRS-CQ12Pd/Na-K(I),GRS-CQ14Pd/Na-K(I),GRS-CQ16Pd/Na-K(I) Model.
Содержание SXVD200LCJ/A-K
Страница 1: ...Air to Water Heat Pump Service Manual T1 R410A 50Hz GREE ELECTRIC APPLIANCES INC OF ZHUHAI...
Страница 3: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP PRODUCT...
Страница 15: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP CONTROL...
Страница 69: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP INSTALLATION...
Страница 81: ...AIR TO WATER HEAT PUMP INSTALLATION 76...
Страница 107: ...GREE COMMERCIAL AIR CONDITIONERS AIR TO WATER HEAT PUMP MAINTENANCE...
Страница 115: ...AIR TO WATERHEATPUMP MAINTENANCE 109 2 Comp Low pressure Protection E3 3 Comp Discharge Temp Protection E4...
Страница 116: ...AIR TO WATERHEATPUMP MAINTENANCE 110 4 Overload proection of compressor or driver error E5 5 Outdoor fan error EF...
Страница 117: ...AIR TO WATERHEATPUMP MAINTENANCE 111 6 Temperature sensor error 7 Communication Malfunction E6...
Страница 121: ...AIR TO WATERHEATPUMP MAINTENANCE 115 3 1 3 Trip Fig 3 1 3 Flowchart of trip diagnosis...
Страница 129: ...AIR TO WATERHEATPUMP MAINTENANCE 123 3 2 3 Tripping Fig 3 2 3 Flowchart of diagnosis of Tripping...
Страница 148: ...AIR TO WATERHEATPUMP MAINTENANCE 142 Indoor Unit 1 Front panel assy Fig 2 Fig 1 Fig 2...
Страница 153: ...AIR TO WATERHEATPUMP MAINTENANCE 147 Exploded View of GRS CQ8 0Pd Na k O and GRS CQ10Pd Na K O...
Страница 155: ...AIR TO WATERHEATPUMP MAINTENANCE 149 Exploded View of GRS CQ12Pd Na K O GRS CQ14Pd Na K O and GRS CQ16Pd Na K O...