Install the drainage hose
For well draining, the drain hose should be
placed at a downward slant.
Do not wrench or bend the drain hose or flood
its end by water.
The prolonged drainage hose should be wrapped
with heat insulation material when going through
indoor unit.
Wrenched
Bend
Flooded
Install the connection pipes
Connect the connection pipes with the relevant
union pipes of the indoor unit and tighten the
flare nut of the connection pipes.
NOTE:
and the outdoor unit secondly.
Connect the connection pipes with the indoor unit firstly
Be careful in bending the connection pipes, or you will
damage the pipes.
If the tightening torque is too great in tightening the
flare nuts, leakage will happen.
Fig.
Electric wiring
Install the piping hole
Make the piping hole in the wall at a slight downward slant, the dimension please refer to fig.11-1.
Insert the piping-hole sleeve into the hole to prevent the connection piping and wiring from being damaged
when passing through the hole.
Open panel upwardly.
Remove the electric box cover.
Make power connect wire through wire hole at rear case and bottom of
electric box from down to up.
(earth wire) to terminal ; and to tighten the power connection wire with cable groove, which is on the
electric box.
As shown in Fig.11-3, connect the blue wire of power connect wire onto termianl
"N(1)", brown onto terminal "2", red onto "3" (there is no red wire in the single-split type unit), yellow-green one
Recover the front panel.
Reinsert the covering plate to the original place, screw in the bolts.
For heat pump unit, the signal control wire via the connection of connector and indoor unit (As shown in
Fig.11-3). Then to tighten the signal control wire with wire clamp on the bottom of unit body case.
Install indoor unit
Cut off tailing 1 when only power cord is routed;
are routed.
Cut off tailings 1 and 2 (thereinto are recommended)when connection pipe and power cord
Wrap the piping and wiring and pull them through the cut-off tailings hole. (Shown in Fig.11-6)
Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and remove the unit body, to
check if it is firm enugh; As shown in Fig.11-7.
The height of indoor unit installation should be 2.0m or more from the floor.
When routing the pipe (wiring) from the left or right side, and cut off the tailings on base of main unit (As shown in
Fig.11-5. The indoor unit piping, tube mill forms refer to Fig.11-4 (a), (b).
Содержание KFR-35GW/NaA512
Страница 1: ...1 Summary and features Models Remarks Ultra thin split unit series...
Страница 2: ...Remarks Models...
Страница 3: ...Remarks Models Ultra thin split unit series...
Страница 11: ...Handle Screw Nut Spanner Ultra thin split unit series...
Страница 12: ...Unit mm Screw Nut Spanner Model H KFR 25 2W NaA512 700 KFR 60W2 NaA512 700 KFR 35 2W NaA512 840...
Страница 14: ...6 6 6 6 6 Circuit diagram...
Страница 47: ...9 Explosive view and spare parts list Explosive view of indoor unit Ultra thin split unit series...
Страница 49: ...Explosive view for outdoor unit of single split type unit Ultra thin split unit series...
Страница 51: ...Ultra thin split unit series Explosive view for indoor unit of dual split type unit...
Страница 53: ...Ultra thin split unit series Explosive view for outdoor unit of dual split type unit...