Install the indoor unit
Install the wall mounting frame
Fig.
Measure horizon by handing line or horizontal
measurement. Since drainage pipe hole is on
left side, when adjusting panel, the left should
never be higher; it is better to make it lower.
Fix the wall mounting frame on the selected
location with screws.
Pull the wall munting frame by hand after
installation to see if ti is firm enough. The
rear panel should be able to stand the weight
of an adult (60kg) and the weight should be
evenly shared by each screw.
Ultra thin split unit series
Electric wiring
All electric installation should accord with the national regulation.
The rated voltage and exlusive circuit of air conditioner must be used, the diameter of power cord should be
big enough.
Please do not pull the power cord at full tilt.
capacity in the fixed circuit (could refer to the following). The air switch should have the magnetic release,
and thermal release function, to make sure that the short circuit and over load be protected.
The earthing must be reliable, it should be connected to the exclusive earthing device of the building, should
ask for the professional to install.There must be air leakage protection switch and air switch with enough
Models
Air switch capacity
Earth wire
min. cross sectional
area
Power cord
of unit min.
cross sectional area
Requirement for earth
The unit is class I, the reliable earth wire should be adopted.
The yellow-green wire in the unit is earth wire, can not be used for other purpose, can not be cut off. Can not be fixed by
tapping screw, otherwise, it can cause the danger of electric shock.
The earth resistance, should accord with the requirement of national standard GB17790.
The users' power supply should be reliably earthed. Please do not connect the earth wire to the places of following:
Water pipe Gas pipe Sewage pipe
And places where the professional considered is not reliable earthed.
Содержание KFR-35GW/NaA512
Страница 1: ...1 Summary and features Models Remarks Ultra thin split unit series...
Страница 2: ...Remarks Models...
Страница 3: ...Remarks Models Ultra thin split unit series...
Страница 11: ...Handle Screw Nut Spanner Ultra thin split unit series...
Страница 12: ...Unit mm Screw Nut Spanner Model H KFR 25 2W NaA512 700 KFR 60W2 NaA512 700 KFR 35 2W NaA512 840...
Страница 14: ...6 6 6 6 6 Circuit diagram...
Страница 47: ...9 Explosive view and spare parts list Explosive view of indoor unit Ultra thin split unit series...
Страница 49: ...Explosive view for outdoor unit of single split type unit Ultra thin split unit series...
Страница 51: ...Ultra thin split unit series Explosive view for indoor unit of dual split type unit...
Страница 53: ...Ultra thin split unit series Explosive view for outdoor unit of dual split type unit...