Fig.
Fig.
Fig.
Capillary
Bolt
Bolt
Liquid valve
Gas valve
4pcs soldered point
Solenoid coil
Operation procedures/pictures
Disassemble four-way valve
To remove the tighten nut from the 4-way valve
loop, take out the loop, and wrap the 4-way valve
with wet gauze, then unsolder the soldered point
which connect on the 4-way valve (4pcs for each
4-way valve), take off 4-way valve.
The soldering procedures should be as quickly as
possible, and should keep the gauze wet, please
note do not burn the compressor lead by soldering
flame. As shown in Fig. 8-46;
Remove the capillary
Unsolder 2pcs capillary assy and 4pcs soldered point
which connected liquid valve and condenser outlet pipe,
take off the capillary sub-assy. As shown in Fig.8-47:
Remove gas valve and liquid valve
Remove 4pcs bolt which fix two gas valve, unsolder
the soldered point which connect the gas valve and
air return pipe, take off gas valve. (Note: When
unsolder the soldered point, the gas valve should be
entirely wrapped with wet cloth, avoid the valve be
damaged by high temp.) screw off 4pcs bolt which
fix the liquid valve, take off liquid valve.
As shown in Fig.8-48;
Ultra thin split unit series
Содержание KFR-35GW/NaA512
Страница 1: ...1 Summary and features Models Remarks Ultra thin split unit series...
Страница 2: ...Remarks Models...
Страница 3: ...Remarks Models Ultra thin split unit series...
Страница 11: ...Handle Screw Nut Spanner Ultra thin split unit series...
Страница 12: ...Unit mm Screw Nut Spanner Model H KFR 25 2W NaA512 700 KFR 60W2 NaA512 700 KFR 35 2W NaA512 840...
Страница 14: ...6 6 6 6 6 Circuit diagram...
Страница 47: ...9 Explosive view and spare parts list Explosive view of indoor unit Ultra thin split unit series...
Страница 49: ...Explosive view for outdoor unit of single split type unit Ultra thin split unit series...
Страница 51: ...Ultra thin split unit series Explosive view for indoor unit of dual split type unit...
Страница 53: ...Ultra thin split unit series Explosive view for outdoor unit of dual split type unit...