DC Inverter U-match Series Cassette Type Unit
33
T-joint converging drain pipes
0~1000mm
Notice:
Specifications of the converging drain pipes should be
applicable to the operating capacity of the units.
(1) Drain branch should be connected to the vertical or horizontal part of the main
drain pipe.
(2) Horizontal pipe should not be connected to the vertical pipe that is on the same
level. It should be connected in the following way:
1) Install 3-way connector of drainage pipe joint, as shown in the left figure.
2) Install drain elbow as shown in the middle figure.
3) Install horizontal pipe as shown in the right figure.
3-way connection of
Drainage pipe joint
Connection of drain elbow
Connection of horizontal pipe
Содержание GUD1 OOW/NhA-X
Страница 9: ...DC Inverter U match Series Cassette Type Unit 5 2 Product Introduction 2 1 Overall Layout...
Страница 71: ......
Страница 91: ...Unidad de tipo cassette DC inverter Serie U match 16 3 Si va a instalar unidades exteriores en fila Prohibido...
Страница 162: ...quipement type cassette s rie U match DC Inverter 16 3 Si des unit s ext rieures sont pos es en ligne Interdit...