DC Inverter U-match Series Cassette Type Unit
39
3.3.2 Electrical Parameters
Model
Power supply
Fuse
capacity
Circuit
breaker
capacity
Min. sectional
area of power
cord
V/Ph/Hz
A
A
mm
2
Indoor
unit
220-240V 1N~50Hz
208-230V 1N~60Hz
3.15
6
1.0
Model
Power supply
Circuit
breaker
capacity
Min. sectional
area of power
cord
V/Ph/Hz
A
mm
2
GUD35W/NhA-T
220-240V 1N~50Hz
208-230V 1N~60Hz
16
1.5
GUD50W/NhA-T
16
1.5
GUD71W/NhA-T
20
2.5
GUD85W/NhA-T
25
2.5
GUD100W/NhA-T
32
4.0
GUD125W/NhA-T
32
4.0
GUD140W/NhA-T
40
6.0
GUD100W/NhA-X
380-415V 3N~50Hz/60Hz
16
1.5
GUD125W/NhA-X
16
1.5
GUD140W/NhA-X
16
1.5
GUD160W/NhA-X
16
1.5
NOTICE:
①
.
Fuse is located on the main board.
②
.
Install a circuit breaker at every power terminal near the units (indoor and
outdoor units) with at least 3mm contact gap. The units must be able to
be plugged or unplugged.
③
.
Circuit breaker and power cord specifications listed in the above table are
determined based on the maximum power input of the units.
④
.
Specifications of power cords listed in the above table are applicable in a
working condition where ambient temperature is 40
℃
and multi-core
copper cable (e.g. YJV copper cable, with insulated PE and PVC sheath)
is protected by a conduit, and is resistant to 90
℃
in maximum (See IEC
60364-5-52). If working condition changes, please adjust the
specifications according to national standards.
⑤
.
Specifications of circuit breaker are based on a working condition where
Содержание GUD1 OOW/NhA-X
Страница 9: ...DC Inverter U match Series Cassette Type Unit 5 2 Product Introduction 2 1 Overall Layout...
Страница 71: ......
Страница 91: ...Unidad de tipo cassette DC inverter Serie U match 16 3 Si va a instalar unidades exteriores en fila Prohibido...
Страница 162: ...quipement type cassette s rie U match DC Inverter 16 3 Si des unit s ext rieures sont pos es en ligne Interdit...