DC Inverter U-match Series Cassette Type Unit
18
Model
H(mm)
GUD35T/A-T
285
GUD50T/A-T
285
GUD71T/A-T
260
GUD85T/A-T
260
GUD100T/A-T
260
GUD125T/A-T
310
GUD140T/A-T
310
GUD160T/A-T
310
3.2 Unit Installation
3.2.1 Indoor Unit Installation
In order to make the front panel cover 20mm of the ceiling, the distance
between the ceiling and the unit should be 35mm or less. If the distance between
the ceiling and the unit is above 35mm, add some ceiling material to shorten the
distance. See the following diagram.
Ceiling material
≤35mm
≤35mm
3.2.1.1 Hoisting the Main Body Unit
NOTICE
Please tightly screw up the nuts and bolts to prevent the air conditioner from
falling.
(1) Installing the Suspension Bolts.
1) Using the installation template, drill holes for bolts (four holes).
2) Install the bolts to the ceiling at a place strong enough to hang the unit.
Mark the bolt positions from the installation template. With a concrete drill,
drill for 12.7 mm (1/2") diameter holes.
3) Insert the anchor bolts into the drilled holes, and drive the pins completely
into the anchor bolts with a hammer.