4 Specifications
4.1 Specifications
Model
GMV-120W
L/A-T
GMV-140W
L/A-T
GMV-160WL
/A-T
GMV-120W
L/A-X
GMV-140W
L/A-X
GMV-160WL
/A-X
Cooling capacity
kW
12.1 14 16 12.1 14 16
Heating capacity
kW
14 16.5 18.5 14 16.5 18.5
Circulating air
volume
m
3
/h
6000
6300
6600
6000
6300
6600
Noise
dB(A)
55 56 58 55 56 58
Refrigerant
charge volume
kg
5 5 5 5 5 5
Energy efficiency
level
Level
1 1 1 1 1 1
Power supply
220-240V
ᨺ
50Hz 208-230V
ᨺ
60Hz
380-415V 3N~50Hz 380-415V 3N~60Hz
Rated
power
input
Coolin
g
kW
3.05 3.98 4.85 3.05 3.98 4.85
Heatin
g
kW
3.27 3.99 4.67 3.27 3.99 4.67
Unit Dimensions
(mm)(WxDxH)
900×340×1345
Package Dimensions
(mm)(WxDxH)
998×458×1515
Compressor QXAS-F428zX050A QXAS-F428zX050C
Water-proof level
IPX4
IPX4
IPX4
IPX4
IPX4
IPX4
Suitable
climite T1 T1 T1 T1 T1 T1
Connect
ion pipe
Gas
mm
Ф15.9
Ф15.9
Ф19.05
Ф15.9
Ф15.9
Ф19.05
Liqui
d
mm
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Ф9.52
Connection
Method
Bell mouth
connection
Bell mouth
connection
Bell mouth
connection
Bell mouth
connection
Bell mouth
connection
Bell mouth
connection
Net weight
kg
110 110 110 120 120 120
Содержание GMV-100WL/A-T
Страница 1: ...DC INVERTER VRF SYSTEM SERVICE MANUAL R410A...
Страница 4: ...DC INVERTER VRF SYSTEM II SERVICE MANUAL R410A PRODUCT...
Страница 15: ...GREE DC Inverter Multi VRF System II Service Manual 11 GMV 80WL C T GMV 100WL C T GMV 121WL C T...
Страница 16: ...GREE DC Inverter Multi VRF System II Service Manual 12 GMV 141WL C T...
Страница 18: ...GREE DC Inverter Multi VRF System II Service Manual 14 CONTROL...
Страница 33: ...GREE DC Inverter Multi VRF System II Service Manual 29 z Click Next z Installation is in progress...
Страница 58: ...GREE DC Inverter Multi VRF System II Service Manual 54 Step 4 Then click Port Settings in the dialog box...
Страница 64: ...GREE DC Inverter Multi VRF System II Service Manual 60 INSTALLATION...
Страница 72: ...GREE DC Inverter Multi VRF System II Service Manual 68 DEBUGGING MAINTENANCE...
Страница 104: ...GREE DC Inverter Multi VRF System II Service Manual 100 GMV 141WL C T GMV 120WL A T GMV 140WL A T GMV 160WL A T...
Страница 107: ...GREE DC Inverter Multi VRF System II Service Manual 103 GMV H280WL A X GMV 280WL C X GMV H335WL A X GMV 335WL C X...
Страница 173: ...JF00302323...