GREE DC Inverter Multi VRF System II Service Manual
75
Description of each stage of debugging progress
——
Debugging code
Code meaning and operation method
Progress
LED
Code
Display status
10/oC
Display
circularly
Valves status is normal. Unit will display as in the left for 2s and
then start next step.
12_ Confirm
debugging startup
12/AP
Display
circularly
Ready for units to start debugging. Press main board’s SW3
button to confirm startup of debugging. 2s later, main board will
display as below:
12/AE
Display
circularly
Startup is confirmed. After displaying for 2s, system will choose
“15_Cooling debugging” or “16_Heating debugging” according to
ambient temperature. If the project requests to add refrigerant
but it is not complemented before debugging, then refrigerant
can be added in this process through the L-VALVE.
15_ Cooling
debugging
15/AC
Display
circularly
Debugging for cooling mode. If no malfunction occurs for 50min
when compressor is running, then the system is certified as
normal. After shutting down the unit for 5s, the system will enter
normal standby status.
15/error code
Display
circularly
Malfunction occurs when debugging for cooling mode.
16_ Heating
debugging(For
heat pump units
only)
16/AH
Display
circularly
Debugging for heating mode. If no malfunction occurs for 50min
when compressor is running, then the system is certified as
normal. After shutting down the unit for 5s, the system will enter
normal standby status.
16/error code
Display
circularly
Malfunction occurs when debugging for heating mode.
17_ Debugging
finished
oF ON
The entire unit has finished debugging and under standby-by
condition.
1.3 Parameters reference value for the normal operation of unit
No.
Debugging project
Parameters name
Unit
Reference value
1
Paramers
of system
Parameters
of outdoor
unit
Outdoor ambient
temperature
ć
——
2
Discharge
temperature of
compressor
ć
●After compressor is started up, normal discharge
temperature for cooling is 70~105
ć
, which is 10
ć
above
more than the high pressure saturation temperature.
●The normal temperature for heating is 65
ć
~90
ć
, which is
10
ć
above more than the high pressure saturation
temperature.
3
Defrosting
temperature
ć
●During cooling operation, defrosting temperature is 4~10
ć
lower than the high pressure value of system;
●During heating operation, defrosting temperature is
almost
equal to the low pressure value of system (the disffrence is
withing 2
ć
).
4
High pressure of
system
ć
●Under cooling mode, the normal high pressure value is
20
ć̚
55
ć
. According to the change of ambine
temperature and operation capacity of system, the high
pressure value of system is 10
ć̚
30
ć
higher than the
ambient temperature. The higher the ambient temperature,
the temperature difference is small; Under cooling operation
at the ambient temperature of 25~35
ć
, the high pressure
value for the system is 44~53
ć
;
●The unit will operate at heating mode when the ambient
temperature is above -5
ć
. The high pressure value for the
system is 40~52
ć
. When the ambient temperature is low
and the indoor unit is started up frequently, the high pressure
value will be a little lower.
5
Low pressure of
system
ć
●The unit will operate under cooling mode when the ambient
temperature is 25~35
ć
, the low pressure value for the
system is 0~8
ć
.
●The unit will operate under heating mode when the
ambient temperature is above -5
ć
, the low pressure value
Содержание GMV-100WL/A-T
Страница 1: ...DC INVERTER VRF SYSTEM SERVICE MANUAL R410A...
Страница 4: ...DC INVERTER VRF SYSTEM II SERVICE MANUAL R410A PRODUCT...
Страница 15: ...GREE DC Inverter Multi VRF System II Service Manual 11 GMV 80WL C T GMV 100WL C T GMV 121WL C T...
Страница 16: ...GREE DC Inverter Multi VRF System II Service Manual 12 GMV 141WL C T...
Страница 18: ...GREE DC Inverter Multi VRF System II Service Manual 14 CONTROL...
Страница 33: ...GREE DC Inverter Multi VRF System II Service Manual 29 z Click Next z Installation is in progress...
Страница 58: ...GREE DC Inverter Multi VRF System II Service Manual 54 Step 4 Then click Port Settings in the dialog box...
Страница 64: ...GREE DC Inverter Multi VRF System II Service Manual 60 INSTALLATION...
Страница 72: ...GREE DC Inverter Multi VRF System II Service Manual 68 DEBUGGING MAINTENANCE...
Страница 104: ...GREE DC Inverter Multi VRF System II Service Manual 100 GMV 141WL C T GMV 120WL A T GMV 140WL A T GMV 160WL A T...
Страница 107: ...GREE DC Inverter Multi VRF System II Service Manual 103 GMV H280WL A X GMV 280WL C X GMV H335WL A X GMV 335WL C X...
Страница 173: ...JF00302323...