CWT22 USER AND SERVICE MANUAL
Revision: 03/2018 Page: 7
10. Press the key to confirm.
Remarks:
0 0 0
A B C
A --- Buzzer on: 0= Stable not required 1= Stable required
B
–- LCD indicator and RELAY on: 0= Stable not required 1= Stable required
C : Buzzer beeps when: 0= Buzzer off 1= OK 2= LO and HI
Low limit set as 0 will clear all check weigh values.
This function is locked when
UF-5
is set as
“
HoLD 1
”
U F - 3
Auto-power off
Modes:
A o F F 0 0
:Auto-turn off disable.
A o F F 0 1
: The balance will automatically turn off after 1 minute of non use.
This time can be set up to 99 minutes.
1. Press the key to access to auto-power configuration.
2. Use the keys and to move cursor and press the to select
number.
3. Press the key to confirm.
U F - 4
Backlight setting
Modes:
l i t a
: Automatic
l i t o n
: Backlight on
l i t o F F
: Backlight off
1. Press the key to access to backlight configuration.
2. Use the key to select the desired mode.
3. Press the key to confirm.
U F - 5
HOLD function (
*
)
Modes:
H o L d 0
: Disable
H o L d 1
: Animal (motion) Hold function
H o L d 2
: Peak value hold (when held can press any key to cancel)