CWT22  USER  AND  SERVICE  MANUAL 

Revision: 03/2018                                                          Page:  2 

 

Warranty 

Gravity  Measurement,  Inc.  (Schenectady,  New  York)  offers  one-year  limited 

warranty  (parts  and  labor)  for  the  components  failed  due  to  defects  in  materials  or 
workmanship. Warranty starts from the date of delivery. 

During the warranty period, should any repairs be necessary, the purchaser must 

inform its supplier or Gravity Measurement. The company or its authorized technician 
reserves  the  right  to  repair  or  replace  the  components  at  any  of  its  workshops 
depending on the severity of the problems. However, any freight involved in sending 
the faulty units or parts to the service center should be borne by the purchaser. 

The warranty will cease to operate if the equipment is not returned in the original 

packaging and with correct documentation for a claim to be processed. All claims are 
at the sole discretion of Gravity Measurement. 

This warranty does not cover equipment where defects or poor performance is due 

to  misuse,  accidental  damage,  exposure  to  radioactive  or  corrosive  materials, 
negligence, faulty installation, unauthorized modifications or attempted repair or failure 
to  observe  the  requirements  and  recommendations  as  given  in  this  User  Manual. 
Additionally, rechargeable batteries (where supplied) are not covered under warranty. 

Repairs  carried  out  under  the  warranty  does  not  extend  the  warranty  period. 

Components removed during the warranty repairs become the company property. 

 

 

 

 

Содержание CWT22

Страница 1: ...Weighing Scale User and Service Manual Please read this manual carefully before operation Important safety info Warranty Model CWT22 GRAVITY MEASUREMENT INC...

Страница 2: ...extension cords this may cause interference 4 Do not use on surfaces or in areas where vibration air movement or temperature change Do not place in direct sunlight or near air conditioning vents 5 Av...

Страница 3: ...the service center should be borne by the purchaser The warranty will cease to operate if the equipment is not returned in the original packaging and with correct documentation for a claim to be proc...

Страница 4: ...at protrudes through the bottom of the device and through a hole in the scale base adjacent to the metal rode Set up the Scale Place the scale on a stable level surface out of the way of air currents...

Страница 5: ...eight To move one space to the right or upward in setup mode N G To view gross or net weight when the balance is on tare status All other keys will be disabled when gross weight is activated To increa...

Страница 6: ...key to select unit to kg lb or oz that is set up by LF 2 Use a container if necessary and press zero or tare key Press PT key to enter the known weight of your container to pre tare Finally add the c...

Страница 7: ...Press the key to view the A D count 2 Press the key to view the the battery voltage or press the key to exit back to menu UF 1 3 To move to next parameter press the key 4 To exit and return to normal...

Страница 8: ...urn off disable AoFF01 The balance will automatically turn off after 1 minute of non use This time can be set up to 99 minutes 1 Press the key to access to auto power configuration 2 Use the keys and...

Страница 9: ...key to select 1 2 4 8 16 32 or 64 times within the hold range 5 Press the key to confirm UF 6 RS 232 Output 1 Press the key to enter 2 The display will show 232 1 3 Press the key to select the modes...

Страница 10: ...4 output examples Format 3 and format 4 if you want to print the total weight press the key twice and the accumulative weight will be removed Communication Protocol UART signal of EIA RS232 C Format...

Страница 11: ...7 8 1 2 3 1 2 HEAD1 HEAD2 DATA UNIT CR LF UF 7 Speed setting Modes spEED1 Standard speed spEED2 High speed spEED3 Low speed 1 Press the key to enter 2 Press the key to select the desired mode 3 Press...

Страница 12: ...e the compliance issue or wrong performance of the scale Table Availability of UF ECF and LF Functions with Calibration Switch Location and Type Approval Settings The following instructions are intend...

Страница 13: ...platter and press the key to calibrate The scale will return to weighing mode automatically ECF 2 Zero Calibration 1 Press key to enter display will show cALZ 2 Press key to calibrate zero point 3 Th...

Страница 14: ...nd press M to finish zero calibration Display the full capacity 0300 00 Full capacity weights recommended for calibration of the scale or at least 60 F S to assure the accurate weighing it s not allow...

Страница 15: ...W 1 Put 1 3F S test weight and press ON T to enter next step W 2 Put 2 3F S test weight and press ON T to enter next step W 3 Put 100 F S test weight and press ON T to enter next step W 4 Press Print...

Страница 16: ...voltage is lower than 5 6 V Battery neds charging Connect to main adaptor Press T and 6 together to view battery voltage Press CE to return to weighing mode Battery symbol flashing Battery voltage is...

Страница 17: ...CWT22 USER AND SERVICE MANUAL Revision 03 2018 Page 16 LF5 Zero Tracking LF6 Type Approval LF7 Gravity Adjustment LF8 Zero Order information...

Страница 18: ...CWT22 USER AND SERVICE MANUAL Revision 03 2018 Page 17...

Страница 19: ...Cycle use 7 2 7 5 V Initial current less than 1 5 A Leoch Maintenance free Sealed Lead acid Rechargeable Battery DJW6 4 0 6V 4 0AH Constant voltage charge Standby use 6 75 6 90 V Cycle use 7 2 7 5 V...

Страница 20: ...CWT22 USER AND SERVICE MANUAL Revision 03 2018 Page 19 GRAVITY MEASUREMENT INC...