69
Kudos Pro IP
User Manual
Where N is the input/(Q)SFP number and X is the lane.
SFP_
N
_SERIAL_NR=
Logs the module serial number, which consists of an S
followed by eight digits.
SFP_
N
_REVISION=
Logs manufacturer revision number.
SFP_
N
_CONNECTOR=
Logs connector type.
TEMP_
N
_NAME=
Logs temperature sensor name.
TEMP_
N
_CELSIUS=
Logs current temperature sensor reading.
TEMP_
N
_STATE=
Logs temperature sensor state. Valid values are:
•
WARN:Disabled
- Temperature sensor disabled.
•
WARN:Low
- Low, but in tolerance.
•
WARN:High
- High, but in tolerance.
• OK
•
FAIL:Low
- Low and out of tolerance.
•
FAIL:High
- High and out of tolerance.
VOLTAGE_
N
_NAME=
Logs voltage sensor name.
VOLTAGE_
N
_VALUE=
Logs current voltage reading.
VOLTAGE_
N
_STATE=
Logs temperature sensor state. Valid values are:
• OK
•
WARN:Low
- Low, but in tolerance.
•
WARN:High
- High, but in tolerance.
SFP_
N
_WAVELENGTH=
Logs transmit wavelength in nm.
SFP_
N
_
X
_LASER_BIAS=
Logs bias level in mA.
SFP_
N
_
X
_TX_POWER=
Logs transmit power level in dBm.
SFP_
N
_
X
_TX_POWER_
STATE=
Logs transmit power level. Valid values are:
•
OK
•
WARN:Low
- Low, but in tolerance.
•
WARN:High
- High, but in tolerance.
•
FAIL:Low
- Low and out of tolerance.
•
FAIL:High
- High and out of tolerance.
SFP_
N
_
X
_RX_POWER=
Logs receive power level in dBm.
SFP_
N
_
X
_RX_POWER_
STATE=
Logs receive power level. Valid values are:
•
OK
•
WARN:Low
- Low, but in tolerance.
•
WARN:High
- High, but in tolerance.
•
FAIL:Low
- Low and out of tolerance.
•
FAIL:High
- High and out of tolerance.
Log Field
Description