19
Technical Specifications
Inputs/Outputs
Signal Inputs
Inputs
Up to 12 (0/4/8/12)
Connector/Format
HD-BNC/75R panel jack on standard connector panel
Conforms to
3G-SDI to SMPTE 424M/425M level A compatible
HD-SDI to SMPTE292M/274M/296M
SD-SDI to SMPTE259M-C
Input cable length
Belden 1694A @ 3 Gbit/s - 80m
Belden 1694A @ 1.5 Gbit/s - 140m
Belden 1694A @ 270 Mbit/s - 350m
Signal Outputs
Outputs
Up to 12 (0/4/8/12)
Connector/Format
HD-BNC/75R
Conforms to
3G-SDI to SMPTE 424M/425M level A compatible
HD-SDI to SMPTE292M/274M/296M
SD-SDI to SMPTE259M-C
Ethernet
Connector/Format
10GbE = SFP+
Conforms to
IEEE 802.3by - 10 Gigabit Ethernet over fiber
IEEE 802.3 - 10 Gigabit Ethernet over twinaxial cables
ST2110-10/20/30
SMPTE-291M/IETF RTP Payload for Ancillary Data
VC-2
AES'67
IEEE-1588v2/SMPTE-2059-2
Video Standards
1125 (1080)/50p (A), 1125 (1080)/59p (A),
750 (720)/50p, 750 (720)/59p,
1125 (1080)/25i, 1125 (1080)/29i,
625 (576)/25i, 525 (480)/29i
Latency
IP Sender: < 1 line (ignoring compression codec latency)
IP Receiver: N->(N+1) frames*
*This is dependent on the setting N, currently 0/1/2/3, for the number
of frames of delay applied in the packet store buffer. With N=0, the
minimum delay is approximately 32 lines by default.
VC2 codec latency is approx. 6 lines for both encode and decode.