RollCall Control Panel

Logging - SFP

Log Field

Description

SFP_

N

_FITTED=

Logs presence of (Q)SFP. Valid values are:

• OK

• Missing

SFP

_N

_STATUS=

Logs status reported by the (Q)SFP. Valid values are:
SFPs

• OK

• WARN:Temp

• WARN:VCC

• WARN:TX BIAS

• WARN:RX BIAS

• WARN:Laser

• WARN:TEC  Curr

• FAIL:SFP Not Ready

• FAIL:RX LOS - RX Failure

• FAIL:TX Fault - TX Failure

• FAIL:RX LOL - RX Loss of Lock

• FAIL:TX LOL - TX Loss of Lock

QSFPs

• OK

• WARN:Temp

• WARN:VCC

• WARN:RX  PWR  LO

• WARN:RX  PWR  HI

• WARN:TX  PWR  LO

• WARN:TX  PWR  HI

• FAIL:SFP Not Ready

• FAIL:RX LOS - RX Failure

• FAIL:TX LOS - TX Failure

• FAIL:EQ Fault - EQ Failure

• FAIL:RX LOL - RX Loss of Lock

• FAIL:TX LOL - TX Loss of Lock

• FAIL:Temp

• FAIL:VCC

QSFPs (cont)

• FAIL:RX  PWR  LO

• FAIL:RX  PWR  HI

• FAIL:TX  BIAS  LO

• FAIL:TX  BIAS  HI

• TX  PWR  LO

• TX  PWR  HI

SFP_

N

_TYPE=

Logs (Q)SFP identifier from device.

SFP_

N

_VENDOR=

Logs (Q)SFP manufacturer from device.

SFP_

N

_VENDOR_PN=

Logs (Q)SFP model number from device.

Содержание Kudos Pro LC4000

Страница 1: ...User Manual IP Interface Supplement Issue 2 Revision 1 1 1 01 12 KUDOS PRO IP STANDARDS CONVERTERS WITH IP INTERFACE Kudos Pro IP LC Kudos Pro IP MC Kudos Pro IP SV ...

Страница 2: ...o IP documentation you agree to the following terms and conditions Grass Valley hereby grants permission and license to owners of Kudos Pro IP to use their product manuals for their own internal business use Manuals for GrassValley products may not be reproduced or transmitted in any form or by any means electronic or mechanical including photocopying and recording for any purpose unless specifica...

Страница 3: ...y other equipment connections Identifies an external protective grounding terminal which may be connected to earth ground as a supplement to an internal grounding terminal Indicates that static sensitive components are present which may be damaged by electrostatic discharge Use anti static procedures equipment and surfaces during servicing The presence of this symbol in or on Grass Valley equipmen...

Страница 4: ...al before connecting power Prior to servicing remove jewelry such as rings watches and other metallic objects To avoid fire hazard use only the fuse type and rating specified in the service instructions for this product or on the equipment To avoid explosion do not operate this equipment in an explosive atmosphere Use proper lift points Do not use door latches to lift or move equipment Avoid mecha...

Страница 5: ...he chassis frame to safely ground unwanted ESD voltages If no wrist strap is available ground yourself by touching the unpainted metal part of the chassis For safety periodically check the resistance value of the antistatic strap which should be between 1 and 10 megohms When temporarily storing a card make sure it is placed in an ESD bag Cards in an earth grounded metal frame or casing do not requ...

Страница 6: ...e borne de mise à la terre externe qui peut être connectée en tant que borne de mise à la terre supplémentaire Signale la présence de composants sensibles à l électricité statique et qui sont susceptibles d être endommagés par une décharge électrostatique Utilisez des procédures des équipements et des surfaces antistatiques durant les interventions d entretien Le symbole ci contre signifie que l a...

Страница 7: ... aérosol Utilisez uniquement un chiffon humide Des tensions dangereuses peuvent exister en plusieurs points dans cet équipement Pour éviter toute blessure ne touchez pas aux connexions ou aux composants exposés lorsque l appareil est sous tension Avant de procéder à toute opération d entretien ou de dépannage enlevez tous vos bijoux notamment vos bagues votre montre et autres objets métalliques Po...

Страница 8: ...eut se produire lorsque des composants électroniques ne sont pas manipulés de manière adéquate ce qui peut entraîner des défaillances intermittentes ou endommager irrémédiablement un circuit électrique Au moment de remplacer une carte dans un châssis prenez toujours les mesures de protection antistatique appropriées Assurez vous que le châssis est relié électriquement à la terre par le cordon d al...

Страница 9: ...inutes d utilisation Si l écran LCD ou TFT est brisé manipulez les fragments de verre avec précaution au moment de vous en débarrasser veillez à ce que le cristal liquide n entre pas en contact avec la peau ou la bouche En cas de contact avec la peau ou les vêtements laver immédiatement à l eau savonneuse Ne jamais ingérer le liquide La toxicité est extrêmement faible mais la prudence demeure de m...

Страница 10: ...cycling information Grass Valley believes this environmental information to be correct but cannot guarantee its completeness or accuracy since it is based on data received from sources outside our company All specifications are subject to change without notice If you have questions about Grass Valley environmental and social involvement WEEE RoHS REACH etc please contact us at environment grassval...

Страница 11: ...he battery from its holder using a blunt instrument for leverage such as a screwdriver if necessary In some cases the battery will need to be desoldered from the PCB 4 Dispose of the battery and equipment according to your local environmental laws and guidelines WARNING Be careful not to short circuit the battery by adhering to the appropriate safe handling practices Do not dispose of batteries in...

Страница 12: ...ating conditions Unused optical outputs should be covered to prevent direct exposure to the laser beam Even though the power of these lasers is low the beam should be treated with caution and common sense because it is intense and concentrated Laser radiation can cause irreversible and permanent damage of eyesight Please read the following guidelines carefully Make sure that a fiber is connected t...

Страница 13: ...l SIGNAL DATA PORTS For unconnected signal data ports on the unit fit shielding covers For example fit EMI blanking covers to SFP type ports and fit 75 Ώ RF terminators to BNC type ports COAXIAL CABLES Coaxial cables connections particularly serial digital video connections shall be made with high quality double screened coaxial cables such as Belden 8281 or BBC type PSF1 2M and Belden 1694A for 3...

Страница 14: ...xiv Notices ...

Страница 15: ...rface Card Rear Panel View 18 Feature Summary 18 2 Technical Specifications 19 3 Connections 21 SDI BNC Input Outputs 21 10G Ethernet SFP 21 SFP Link LED Indicators 21 Cabling 21 4 Card Edge LEDs 23 5 RollCall Control Panel 25 Terminology 25 Navigating Pages in the RollCall Template 25 Template Pages 25 Setting Values 26 Information Display 27 Selecting the Information to Display 27 Configuration ...

Страница 16: ...ination Timing 49 Audio V Fade 50 Audio Type Control 51 Input Loss Control 52 Spigot Pages 53 Input Spigots 53 Output Spigots 56 Spigot Pane 56 Flow Panes Primary and Secondary 57 Logging SDI Info 59 Logging System 60 Logging Network 64 Logging SFP 67 Logging FPGA 70 Logging Spigot 71 Logging NMOS 73 Logging Card Diagnostics 74 RollTrack 75 Disable All 75 RollTrack Index 75 RollTrack Source 75 Rol...

Страница 17: ...ption The IQMIX10KP is a multi channel video over IP transceiver module developed for use within low latency high bandwidth Ethernet IP networks capable of encoding decoding multiple SDI signals It provides both compressed and uncompressed modes of operation Encapsulation of signals in a SMPTE 2022 6 transport stream can also be handled to provide compatibility with other video over IP solutions R...

Страница 18: ... RTP Payload for Ancillary Data Supports frame synchronized SDI outputs referenced to IEEE 1588v2 PTP network timing compliant with SMPTE 2059 2 for black burst tri level syncs Low delay mode and Independent H V offset available for each channel along with up to 2 frames of video delay and up to 255ms of audio delay Supports uni cast as well as IGMPv3 source specific multi cast allowing point to p...

Страница 19: ...SDI to SMPTE259M C Ethernet Connector Format 10GbE SFP Conforms to IEEE 802 3by 10 Gigabit Ethernet over fiber IEEE 802 3 10 Gigabit Ethernet over twinaxial cables ST2110 10 20 30 SMPTE 291M IETF RTP Payload for Ancillary Data VC 2 AES 67 IEEE 1588v2 SMPTE 2059 2 Video Standards 1125 1080 50p A 1125 1080 59p A 750 720 50p 750 720 59p 1125 1080 25i 1125 1080 29i 625 576 25i 525 480 29i Latency IP S...

Страница 20: ...en flashing 1 12 Input standard detection LEDs UHD Green 3G Green HD Green SD Yellow None Red SFP LEDs Red Fault rear assembly 3V3 regulator failure Green 10G Logging Input Status Input Alarms Output Alarms Output Status Misc RollTrack controls On off Index Source Address Command Status Sending Setup Versions reset defaults restart Specifications Connector Format HD BNC Power Consumption Complete ...

Страница 21: ...ndicate the following Red Fault 3V3 regulator failure Green OK 10G If the LED is flashing the link is down Cabling Cables should be run between the IQMIX10KP and the Kudos Pro converter in the same way as they would if the card was mounted conventionally in an enclosure No special arrangements are required 10 x 3G HD SD SDI interfaces provided with HD BNC SFP supporting 10G Ethernet ...

Страница 22: ...22 Connections Cabling ...

Страница 23: ...flashing PTP SYNC OK Off PTP SYNC Fail PTP REF REF Green flashing Watchdog timer OK 8 16 1 16 Input flow status Green UHD Green 3G Green HD Yellow SD Off Not connected For 12G quad link Green Active input flow Red Inactive input flow Yellow TPG is active 7 15 6 14 5 13 4 12 3 11 2 10 1 9 SFP 2 SFP 1 2 Status lane Red Fault 3V3 regulator failure Green 10G SFP OK If flashing link is down SFP 1 PB RE...

Страница 24: ...24 Card Edge LEDs ...

Страница 25: ...n a page view list allowing quick access to any of the pages Template Pages The following pages are available Configuration see page 28 Time Sync Configuration see page 30 Sender TPG Test Pattern Generator see page 35 Receiver TPG Test Pattern Generator see page 36 Counters see page 37 Term Description Essence A general term used to describe an SDI component Video Audio and Data are all essences S...

Страница 26: ...igot 1 n see page 53 Logging SDI Info see page 59 Logging System see page 60 Logging Network see page 64 Logging SFP see page 67 Logging FPGA see page 70 Logging Spigot 1 n see page 71 Logging NMOS see page 73 Logging Card Diagnostics see page 74 RollTrack see page 75 Loopback Router see page 77 Setup see page 78 Ethernet Gb see page 79 Ethernet Arcnet see page 80 Interop see page 81 Setting Value...

Страница 27: ...he SDI Selection and Information Select panes to the right of the Information display Selecting the Information to Display Select the inputs to display data for from the SDI Selection drop down list Select Video Input Status Video Output Status Network Status or Spigot Link Status from the Information Select pane as required The selected information will be displayed on the Information display pan...

Страница 28: ...nd output spigots are currently configured See Card Firmware Software Version below for information on how to change this Where Am I Causes the front edge LEDs to flash allowing the module to be easily identified Genlock Select Genlock type Network click to select PTP Chassis Reference A B click to select an on chassis reference Freerun click to allow free running GUID Displays the absolute unique...

Страница 29: ...he module and implement any changes made Domain RollCall uses domains to partition a network only nodes on the same domain can communicate with one another A domain is uniquely identified with a number and a friendly name alias Set an ID as required then press Take to confirm the change Interface Configuration Displays the IP address for each Ethernet interface Card Firmware Software Version Each ...

Страница 30: ...Unicast this uses multicast for the sync messages and unicast for the follow up messages NTP uses NTP for local clock correction NTP can usually maintain time to an accuracy of around 1 10ms but this value could rise to something on the order of 100ms depending on network congestion asymmetry etc This potentially means that 1 5 frames of misalignment of the local device clocks may be seen across t...

Страница 31: ...n and PTP Delay Request Frequency drop down lists as required Type the appropriate IP number into the PTP Multicast address field PTP Status Displays PTP status information Enable the Details check box to display detailed interface status information reset counters show details for other PTP interfaces etc See PTP Status Details below for more information Save Settings Displayed only if settings o...

Страница 32: ...his counter to increment Unexpected 2 Steps Increments on the reception of a follow_up message but the sync message is indicating 1 step RX Timestamp Errs Increments for every PTP message where the sequence number is as expected but its timestamp is not valid TX Timestamp Errs Increments for every delay_resp message where its sequence number is as expected but its timestamp is not valid Av Delay T...

Страница 33: ...ed within any 2 second period follow_up delay_resp sync announce Clock Steps Back If the IQUCP25 50 receives a time earlier than the last this counter is incremented This could be because of a fault with the grandmaster or because there are multiple grandmasters in the system Clock Blips This increments if the local clock offset is 300ns 300ns Delay Blips This increments if the network delay is 12...

Страница 34: ...34 RollCall Control Panel Time Sync Configuration Histogram pane Visible Clocks Displays the GrandMaster clocks present on the network Visible Clocks pane ...

Страница 35: ...e Click Show Caption to overlay a caption on the video essence Option Operation TPG Select the test pattern to apply to the spigot from the drop down list Audio Freq Select the audio frequency to apply to the spigot from the drop down list Caption Type a caption max 19 characters to optionally be displayed with the test pattern Audio dB Select the dB level to apply to the spigot from the drop down...

Страница 36: ...got by spigot basis Receiver TPG page The following options are available for each spigot If a test pattern is applied either a pattern or a tone the spigot cannot be used for streaming any other essence Option Operation TPG Enable Click to enable TPG on this spigot Caption Enter a caption for the spigot optional Show Caption Click to overlay the caption on the video essence ...

Страница 37: ...37 Kudos Pro IP User Manual Counters The Counters page allows the various counters provided to be cleared down Counters page Click Clear buttons as required ...

Страница 38: ...acturers NMOS effectively provides a control and management layer in addition to the transport layer provided by SMPTE ST2110 See www amwa tv nmos for further information The following facilities are available from this page Option Description Mode Allows Discovery and Connection Management to be disabled This can be useful if troubleshooting an issue Options are Off IS 04 and IS 05 are both disab...

Страница 39: ... click S to save Search Domain displays the current search domain and allows a new one to be defined If required enter a new domain in the NEW field and click S to save Static Displayed if Registry Mode see above is set to Static IP Address displays the current NMOS registry IP address and allows a new one to be defined If required enter a new address in the NEW field and click S to save Registrat...

Страница 40: ... Where am I Check box When enabled the Where Am I function causes the SFP QSFP LEDs for the relevant Ethernet connector to flash Clear Link Change Count If the state of the Ethernet link changes the Link Change Count and Link Change Time fields are updated Click Clear Link Change Count to reset the Link Change Count to zero Switch LLDP Info Displays LLDP information received from the switch that t...

Страница 41: ...r Manual Ethernet 1 and 2 RTP Sender The RTP Sender page displays the amount of data transmitted on a spigot by spigot basis Units are megabits per second Click Enable Stats to display values Ethernet 1 2 RTP Sender page ...

Страница 42: ...ceiver pages display the amount of data received plus details of packet loss on a spigot by spigot basis Units are megabits per second Click Enable Stats to display values click Clear RTP Count or Clear Error Count to zero RTP Sequence Discontinuity or Error counters Ethernet 1 2 RTP Receiver page ...

Страница 43: ...s In order to maximize media port bandwidth utilization if spigot addresses match across multiple interfaces then they are allocated to the same Flow ID This means that if multiple spigots are assigned to the same Flow ID and the IP addresses are only partially complete the module will use the shared flow For example if two spigots share the same flow but one of the spigots is missing from the IP ...

Страница 44: ...ge About Flow IDs In order to maximize media port bandwidth utilization if spigot addresses match across multiple interfaces then they are allocated to the same Flow ID This means that if multiple spigots are assigned to the same Flow ID and the IP addresses are only partially complete the module will use the shared flow For example if two spigots share the same flow but one of the spigots is miss...

Страница 45: ...s In order to maximize media port bandwidth utilization if spigot addresses match across multiple interfaces then they are allocated to the same Flow ID This means that if multiple spigots are assigned to the same Flow ID and the IP addresses are only partially complete the module will use the shared flow For example if two spigots share the same flow but one of the spigots is missing from the IP ...

Страница 46: ...nals to these devices sync bit insertion can be disabled by checking the boxes as required TPG These controls are displayed only when using 12G output SDQS If using Square Division signals enable the SDQS check boxes as required Otherwise Two sample Interleave will be used UHD ST352 Insertion set the ST352 ancillary data type according to how the TPG data is to be output For ST2082 10 output over ...

Страница 47: ...ent HDR Control page A New pane is displayed against output spigots Select options from the drop down menus for each spigot as required then click Take to apply the changes The following options are available Option Description Transfer Function Available values are SDR HDR HLG HDR PQ Other Colorimetry Available values are BT709 BT2020 Other ...

Страница 48: ...48 RollCall Control Panel HDR Control Color Space Available values are YCbCr ICtCp Other Bit Depth Available values are 10bit 10bit Full range Option Description ...

Страница 49: ... Description Genlock Timing V Offset Vertical timing offset in lines Genlock Timing H Offset Horizontal timing offset in pixels Receiver Packet Buffer Frames Delay The receiver packet buffer provides additional buffering for a received IP flow Typically this is required where the IP flow is bursty in nature However increasing buffering can affect the time required to switch between IP flows at a s...

Страница 50: ...age allows audio fading to be applied on a spigot by spigot basis in order to minimize audio disruption When applied the audio will fade down on input loss and perform an audio V fade down then up during input switching Configure as required Audio V Fade page ...

Страница 51: ...nual Audio Type Control The Audio Type Control page allows audio pairs to be marked as carrying PCM or non PCM Only pairs on IP receiver spigots are displayed Audio Type Control page Enable check boxes for pairs carrying PCM ...

Страница 52: ...control of the module s response to signal loss Select as required Input Loss Control page Options upon signal loss are Option Operation Freeze Picture will freeze Black Picture will cut to black TPG Picture will be replaced by TPG output as set on the Sender TPG page See page 35 for more information ...

Страница 53: ...on firmware selected Input Spigots Input spigots are defined by selecting the appropriate firmware version on the Configuration page See Configuration on page 28 for more information Typical Input Spigot page The following facilities are available from this page Note The pages shown here may differ from those seen on your particular system depending on the model and configuration of your IQUCP mod...

Страница 54: ...band metadata regarding the essence flow and its format and are applicable to ST 2110 only If third party equipment is unable to support this the functionality can be disabled or set to On Legacy which ensures that the packet format complies with ST2110 but has no video content Options are Off Extended headers are disabled On Sends extended headers fully compliant with ST2110 20 On Legacy Sends ex...

Страница 55: ...ed spigot To set multicast details for the spigot Enter IP and Port details as required Enter the appropriate details in the Source IP and Source Port fields Each spigot can support a variety of flows Select the required flow type from the Flow Type menu Click S to save the details for each item Click Packetizer Stats to view network statistics for the flow if required Option Operation ...

Страница 56: ... by selecting the appropriate firmware version on the Configuration page See Configuration on page 28 for more information Typical Output Spigot page Spigot Pane The Spigot pane provides basic monitoring for the selected Spigot Click Take to apply any changes made Output Spigot Pane ...

Страница 57: ...the number of audio channels is known select the number present on this spigot Otherwise set to Auto Audio Delay Move the slider to set an Audio Delay as required Click P to return to the preset default value Make Break Mode Specifies how changes to an output s destination will be made Make before Break causes the new destination to buffer data before connection to the previous destination is brok...

Страница 58: ...quired video standard from the drop down list Enter multicast IP and port details as required Enter the appropriate details in the Source IP and Source Port fields Each spigot can support a variety of flows Select the required flow type from the Flow Type menu Click S to save the details or P to return to the preset default value ...

Страница 59: ...r which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value The information below describes the various parameters available for logging Logging SDI Info page The following facilities are available from this page Where N is the input number Log Field Description INPUT_N_CHANGE_TIME Logs time that the SDI input changed INPUT_...

Страница 60: ...a logging device connected to the RollCall network Each logging page comprises three columns Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value Logging System page ...

Страница 61: ...ARE_VERSION Reports the firmware version number UPTIME Reports the time since the last restart in the format ddd hh mm ss RC_UPTIME Reports time RollCall has been up in the format ddd hh mm ss ROL_STATES Reports the RollCall status Valid values are OK FAIL n where n is the RollTrack index or indexes which are failing Disabled REAR_ID Reports the code number of the rear fitted REAR_STATUS Reports t...

Страница 62: ...TIMESYNC_N_CLOCK_ STATE Valid values are Free running Card is not being synchronized No Lock PTP being used but clocks haven t synchronized within 1mS Locked PTP being used and clocks are within the accepted range NTP Module using NTP to synchronize TIMESYNC_N_AVG_ DELAY The current network delay time between the card and the clock sending the synchronization messages This should be relatively con...

Страница 63: ...ll be a low number as cards are expected to synchronize and stay synchronized Large numbers indicate possible problems with the network or grandmaster clock TIMESYNC_N_STATE Logs whether PTP is locked Valid values are OK LOCKED FAIL NO LOCK TIMESYNC_N_CLOCK_ ADDRESS Logs IP address of the currently selected Grand Master TIMESYNC_N_REQUEST_ INTERVAL Logs the PTP Delay Request Frequency setting as s...

Страница 64: ... a logging device connected to the RollCall network Each logging page comprises three columns Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value Logging Network page ...

Страница 65: ... address LAN_PORT_N_STATE Logs the Ethernet connection state Valid values are Active WARN Inactive LAN_PORT_N_TRAFFIC_IN Logs speed of traffic received by the Ethernet port Values are reported in kbps Mbps or Gbps as appropriate LAN_PORT_N_TRAFFIC_OUT Logs speed of traffic transmitted by the Ethernet port Values are reported in Kbps Mbps or Gbps as appropriate LAN_PORT_N_CPU_TRAF_IN_ STATE Shows w...

Страница 66: ...e module is connected to LAN_PORT_N_SWITCH_CHASSIS _ID Logs the MAC address of the switch port to which the module s media port is connected LAN_PORT_N_SWITCH_PORT_ ID Logs Port ID of the network switch the module is connected to LAN_PORT_N_SWITCH_PORT_ VLAN Logs name of the VLAN that the module is connected to Log Field Description ...

Страница 67: ...Each logging page comprises three columns Log Enable Select the check boxes that correspond to the parameters for which log information should be collected Log Field Displays the name of the logging field Log Value Displays the current log value Logging SFP page The following options are available Enable check boxes to activate log fields as required ...

Страница 68: ...X LOL RX Loss of Lock FAIL TX LOL TX Loss of Lock QSFPs OK WARN Temp WARN VCC WARN RX PWR LO WARN RX PWR HI WARN TX PWR LO WARN TX PWR HI FAIL SFP Not Ready FAIL RX LOS RX Failure FAIL TX LOS TX Failure FAIL EQ Fault EQ Failure FAIL RX LOL RX Loss of Lock FAIL TX LOL TX Loss of Lock FAIL Temp FAIL VCC QSFPs cont FAIL RX PWR LO FAIL RX PWR HI FAIL TX BIAS LO FAIL TX BIAS HI TX PWR LO TX PWR HI SFP_...

Страница 69: ...ogs voltage sensor name VOLTAGE_N_VALUE Logs current voltage reading VOLTAGE_N_STATE Logs temperature sensor state Valid values are OK WARN Low Low but in tolerance WARN High High but in tolerance SFP_N_WAVELENGTH Logs transmit wavelength in nm SFP_N_X_LASER_BIAS Logs bias level in mA SFP_N_X_TX_POWER Logs transmit power level in dBm SFP_N_X_TX_POWER_ STATE Logs transmit power level Valid values a...

Страница 70: ...The following options are available Enable check boxes to activate log fields as required Where N is the input number Log Field Description TEMP_N_NAME Reports temperature sensor name TEMP_N_CELSIUS Reports current temperature sensor reading TEMP_N_STATE Reports current temperature state Valid values are WARN Low temperature is low but in tolerance WARN High temperature is high but in tolerance OK...

Страница 71: ...elds are shown An additional field is provided for the user to optionally specify a name for the input output Input Spigot Logging page Output Spigot Logging page The following options are available Enable check boxes to activate log fields as required Option Description INPUT_N_IDENT System defined identifier for the input based on the rear ID INPUT_N_NAME Name of the input as defined on the Setu...

Страница 72: ...the rear panel OUTPUT_N_NAME Name of the output as defined by the user OUTPUT_N_STATE Current state of the output Valid values are OK output signal good FAIL output signal not detected WARN Freeze WARN Pattern WARN Black OUTPUT_N_TYPE Type of output Valid values are SD SDI HD SDI HD SD 3G SDI OUTPUT_N_STANDARD Reports video standard on the output Format Lines Active Rate i p sf Where Lines Total l...

Страница 73: ...re N is the input output number Option Description NMOS_STATUS Displays the current NMOS status Valid values are OK Off NMOS functionality is disabled OK Registered the module has been successfully added to the NMOS registry WARN Registering the module is currently being registered FAIL Unregistered the registration process has failed NMOS_REGISTRATION Displays the method used to register the modu...

Страница 74: ...red Option Description NVRAM_FS Logs whether the installed file system is QNX6 PowerSafe or FAT32 TOTAL_AVAILABLE_ MEMORY Logs total amount of CPU memory available to the module in bytes TOTAL_USED_MEMORY Logs amount of CPU memory used by the module in bytes NUM_CORE_DUMPS Logs number of times a core dump has been performed as a result of an application crash LAST_CORE_DUMP_ NAME Logs name of last...

Страница 75: ...th this control Dragging the slider selects the RollTrack source displayed below the slider Clicking P selects the default preset value When no source is selected Unused is displayed Where N is the input number RollTrack Address This item enables the address of the selected destination unit to be set The address may be changed by typing the new destination into the text field then clicking S to sa...

Страница 76: ...cond number 156 is the value sent with the RollTrack command RollTrack Sending A message is displayed here when the unit is actively sending a RollTrack command Possible messages are RollTrack Status A message is displayed here to indicate the status of the currently selected RollTrack index Possible RollTrack Status messages are Log Field Description No The message is not being sent Yes The messa...

Страница 77: ...p in case of Ethernet failure Loopback Router page If an Ethernet failure is encountered 1 Use the matrix radio buttons to specify which inputs should be routed to which outputs 2 Select the Video Flow to Use SMPTE 2022 RFC4175 or VC2 3 When set as required click the Enable Router Control check box to activate routing ...

Страница 78: ...ou need technical assistance Item Description Product Name of the module Software Version Currently installed software version number Firmware Version Currently installed firmware version number Serial No Module serial number SW Build Factory software build number This number identifies all parameters of the module OS Operating system version number Rear ID Rear panel type Firmware Build Set Firmw...

Страница 79: ...isplays details of the currently selected network interface and allows a static IP address to be defined Enter information as required then click S to save New settings are applied when Restart is clicked Daughter Mod Level Daughter board PCB modification level Daughter HW Build Factory daughter board hardware build number Note Restarting the module will affect all outputs Option Description Defau...

Страница 80: ...80 RollCall Control Panel Ethernet Arcnet Ethernet Arcnet Not currently used Ethernet Arcnet page ...

Страница 81: ...P User Manual Interop The Interop page allows certain parameters to be changed in order to improve interoperability with third party equipment Interop page The following facilities are available from the Interop page ...

Страница 82: ...o synchronize RTP to PTP Nominal Delay Enable to set nominal delay at the spigot RTP Enable to use RTP timestamps only to synchronize metadata to video Meta Frame Delay Allows a frame delay for metadata received on the spigots shown to be set Use the sliders to adjust as required Click P to use the preset default value RTP Payload Types Payload Selection Set 1 Set 2 Select the appropriate set of s...

Страница 83: ...in a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from the website Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Отзывы: