background image

Order No.

Item No.

Part Description

BC0-CB-0044-00

COMET 145-1

Cabinet Cleanout Cover

BC0-CB-0043-00

COMET 145-2

Cabinet Coil Cover

BC0-CB-0046-00

COMET 145-3

Cabinet Lower Front Cover (L/R)

3TC-05-K260-00

COMET 145-4A

K26 Tankless Coil 

3TC-05-K25M-00

COMET 145-4B

K25m Tankless Coil (Round -Not Shown)

B00-PV-0424-00

COMET 145-5

Flue Gas Baffles

3GK-00-COIL-00

COMET 145-6A

Coil Gasket for K26

3GK-00-COIL-01

COMET 145-6B

Coil Gasket for K25m (Round -Not Shown)

BCF-PV-0020-00

COMET 145-7

Collector Cover

BC0-PV-0081-00

COMET 145-8

Collector Cover Gasket Set

BC0-CB-040A-00

COMET 145-9A

Cabinet Side Panels  (Left)

BC0-CB-040B-00

COMET 145-9B

Cabinet Side Panels  (Right)

BCF-PV-0010-00

COMET 145-10A

Pressure Vessel Assembly

BCA-PV-0010-00

COMET 145-10B

Pressure Vessel Assembly

BCF-CB-0110-00

COMET 145-11A

Cabinet Top

BCA-CB-0110-00

COMET 145-11B

Cabinet Top

BCF-CB-0010-00

COMET 145-12

Boiler Jacket

3CC-00-WALL-03

COMET 145-13

Target Wall

BCF-PV-0022-00

COMET 145-14

Rear Cover

BCF-CB-0130-00

COMET 145-15

Cabinet Rear Panel

4TD-00-PG75-00

COMET 145-16

Tridicator (Not Shown)

4AQ-00-L102-9B

COMET 145-17

Aquastat L8124L1029B (Not Shown)

3BN-0F-3LBT-00

COMET 145-18

40F3 Riello (Long Tube)

3BN-0F-5LBT-00

COMET 145-19

40F5 Riello (Long Tube)

3BN-BF-3LBT-00

COMET 145-20

BF3 Riello Direct Vent (Long Tube)

3BN-BF-5LBT-00

COMET 145-21

BF5 Riello Direct Vent (Long Tube)

3BN-00-PA70-10

COMET 145-22

AFII-85-90 Beckett Burner PA #701

3BN-00-PA90-10

COMET 145-23

AFII-100 Beckett Burner DV PA #901

3BN-00-PA60-10

COMET 145-24

AFII-150-90- Beckett Burner PA #601

Comet 145 Oil-Fired Boiler

Table - 1

Please have serial number & date of manufacture ready when ordering parts

June-06

Содержание Comet 145

Страница 1: ...THAT MAY DIFFER FROM THIS MANUAL Please read this complete manual before beginning installation These instructions must be kept with the boiler for future reference CERTIFIED TO CAN CSA Std B140 0 St...

Страница 2: ...0 Installation 4 2 1 Important 4 2 2 Caution 4 2 3 General Instructions 4 2 4 Placement Venting 4 2 5 Boiler Configuration 5 2 6 Assemble Boiler 5 2 7 Domestic Hot Water 6 2 8 Assemble Install Burner...

Страница 3: ...lation Figure 5 Cleaning Figure 6 Cabinet Assembly Figure 7 Dimensions Figure 8 Exploded Parts Table 1 Parts List Keep this manual in a safe place for future reference Follow manual carefully for the...

Страница 4: ...DO NOT ATTEMPT TO START BURNER WHEN EXCESS OIL HAS ACCUMULATED WHEN UNIT IS FULL OF VAPOUR OR COMBUSTION ZONE IS VERY HOT NEVER BURN GARBAGE OR PAPER IN THE UNIT AND NEVER STORE COMBUSTIBLE MATERIAL A...

Страница 5: ...ION INSTALLATION MUST COMPLY WITH REGULATIONS OF AUTHORITIES HAVING JURISDICTION DO NOT START THE BURNER UNTIL ALL FITTINGS COVERS AND DOORS ARE IN PLACE DO NOT TAMPER WITH THE BOILER OR CONTROLS 2 3...

Страница 6: ...e section 2 8 ASSEMBLE INSTALL BURNER AQUASTAT Honeywell L8124L1029 and White Rogers 8B43A 601 or certified equivalent For remote bulb use Honeywell L8151A1052 The Triple Aquastat can be located on th...

Страница 7: ...o correspond with boiler settings table shown on operating decal or section 7 0 BURNER SPECIFICATIONS INSTALL NOZZLE Install selected nozzle and make sure it is tight in the nozzle adapter ELECTRODES...

Страница 8: ...nk gauge protectors and outlet protectors are available at your local dealer ONE PIPE SYSTEM Where the tank is above the burner and when the oil flows by gravity to the oil pump a single stage fuel un...

Страница 9: ...NER Make sure power and fuel are off CLEAN TUBES Clean the tubes carefully with a 2 fiber bristle brush DO NOT DAMAGE TARGET WALL VACUUM Vacuum out lower burner chamber REPLACE BURNER Check insertion...

Страница 10: ...31 CB5 2 1 00 3 79 0 85 60B 7 00 pin 0 118 000 35 CB5 3 1 18 4 47 1 00 60B 7 50 pin 0 140 000 41 Direct Vent BCF V2 0110 10 15 CV3 1 Riello 40 BF3 0 61 3 48 0 50 80B 150 4 10 1 00 74 000 22 CV3 2 0 73...

Страница 11: ...ar as possible 5 Insert the threaded tube end into the pierced hole of the flue vent pipe 6 Install the securing nut on the safety switch tube which protrudes into the flue vent pipe Tighten the nut s...

Страница 12: ...ue temperature is 575 F DRAFT non Direct Vent only Breech Pressure 0 04 wc CONTROLS AQUASTAT Honeywell L8124L1029 L8124G1020 White Rodgers 8B43A 601 Erie Boss 2400 Series Optional Remote Honeywell L81...

Страница 13: ...8 Liters 73 89 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE FOR MOST RECENT UPDATES PLEASE VISIT www GranbyIndustries com The following form MUST be completed for the warranty to be valid Insta...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ......

Страница 21: ......

Страница 22: ...00 COMET 145 10B Pressure Vessel Assembly BCF CB 0110 00 COMET 145 11A Cabinet Top BCA CB 0110 00 COMET 145 11B Cabinet Top BCF CB 0010 00 COMET 145 12 Boiler Jacket 3CC 00 WALL 03 COMET 145 13 Targe...

Отзывы: