5.3.
WIRING CONNECTION AND ELECTRICAL SAFETY FOR SBD50-SOLAR
5.3.1.Battery Setup
Battery setup, such as charging, safety, etc., is needed before proceeding to wiring installation. The required
battery will be a AGM Battery type (12V, 70 Ampere-hour)
5.3.1.1.
Battery Safety
a.
Keep batteries in a place where children cannot reach.
b.
Red color stands for positive, black for negative. Please connect the pole of the batteries
correctly.
c.
Do not attempt to disassemble or modify by yourself, otherwise the sulfuric acid and lead
inside the battery will cause damage to the human body and the environment.
d.
Avoid the batteries from being continual undercharging and overcharging. Continual
undercharging and overcharging will reduce the battery capacity and shorten the battery
life span.
e.
Do not short circuit the positive and negative terminal, otherwise it will easily cause electric
shock, fire or breakdown.
f.
Please always disconnect the main power supply upon installation.
g.
Please do not use the battery as AC power. Converter like UPS is essential for AC purpose.
h.
Do not charge the battery in a sealed container or in upside down position. It is
recommended to charge the battery in a well-ventilated place.
i.
Do not charge the battery near a heater, or place where heat accumulation may occur. Do
not charge the battery in direct sunlight.
j.
Do not dispose the battery in water, fire, and don not heat the batteries.
k.
Do not put your face near the top of the batteries. Wear gloves, eye protection when you
measure or repair the battery.
5.3.1.2.
Pre-Battery Installation and Charging
a)
Place the battery in a level surface.
(WARNING: Keep battery away from spark and flame)