background image

 

      37/37 

 

 

 

GrainPro® Solar Bubble Dryer™50 Instruction Manual 

 

MA4040RAD0914-9 

 

 

8.25.

 

DO I NEED TO STORE THE SBD50 WHEN I’M NOT USING IT? 

 

Yes. When not in use, it’s recommended to clean the SBD50 properly fold the top cover and drying 
floor, and store it in a clean area free from rodents and objects that could damage it. 

 
8.26.

 

WHAT ARE THE MAINTENANCE REQUIREMENTS FOR THE SBD50? 

 

After using, clean the drying floor and inspect it for cuts or holes. If there are holes or cuts, patch 
them using the repair tape. Put the SBD50 in its carrying bag and store it out of the reach of rodents, 
along with its accessories. Avoid dragging the SBD50 drying floor on rough surfaces.  

 

8.27.

 

WHAT IS THE USEFUL LIFE SPAN OF THE SBD50? 

 

The SBD50 comes with a 1-year warranty for normal wear and tear. However, the SBD50 must be 
used and taken care of according to the instructions in the manual to last several useful years. 

 
 
 

9.

 

WARRANTY CLAUSE 

 
GrainPro® hereby warrants that products sold to Buyers shall be free of defects in workmanship and materials, 
for  a  period  as  follows,  starting  from  the  date  of  shipment  (B/L):  One  year  for  the  GrainPro®  Solar  Bubble 
Dryer™50 (SBD50). 
 
The warranty liability is limited to replacement of defective products within the warranty period at GrainPro’s 
plant in accordance with the provisions specifically and expressly set forth herein. 
 
The Buyer will pay for Products which need to be replaced under warranty, a percentage of the full list price 
according to the ratio between the period, which has passed until replacement, and the full warranty period. 
 
The  Buyer  shall  bear  shipping  costs  for  shipment  of  defective  Products  to  GrainPro,  and  GrainPro  shall  bear 
shipping costs of returning good Products to Buyer. 
 
The Warranty does not cover the cost of any service, work, or material required for the replacement of defective 
Products at the site of installation. 
 
GrainPro shall have no obligation under the warranty to replace defective Products or parts thereof if the defect 
is a result of any of the following: normal wear and tear; damages occurring after delivery, accidents, acts of 
God, or catastrophes, fault or negligence, or improper storage installation, maintenance of the Products. 
 
Replacement costs and shipping charges for Products found not to be under warranty as specified above would 
be paid in full by the Buyer before new/refurbished Products are shipped. 
 
Notwithstanding the above, if the Products include main parts or sub-assemblies purchased by GrainPro from 
other vendors ("Additional Equipment"), then the period and terms of warranty for Additional Equipment are 
limited to the period and terms offered by the vendors of such equipment. 
 
The Buyer agrees that the warranty liabilities of GrainPro shall be and are limited to the express foregoing terms: 
THE EXPRESS WARRANTIES AND OBLIGATIONS SET FORTH ABOVE, ARE AND SHALL BE IN LIEU OF ALL OTHER 
WARRANTIES AND OBLIGATIONS OF GRAINPRO, and EXPRESSED OR IMPLIED. EXCEPT TO THE EXTENT HEREIN 
PROVIDED, GRAINPRO DOES NOT MAKE AND SHALL NOT BE DEEMED TO MAKE ANY WARRANTY WHATSOEVER, 
TO ANY END USER OR TO ANY OTHER PERSON OR PARTY, INCLUDING, WITHOUT LIMITATION, ANY WARRANTY 
OF MERCHANTABILITY OR OF FITNESS FOR ANY PARTICULAR USE OR PURPOSE. GRAINPRO SHALL NOT BE LIABLE 
FOR ANY LOSS OF USE, SALES OR PROFIT OR FOR ANY INDIRECT, CONSEQUENTIAL OR INCIDENTAL DAMAGES 
CAUSED BY OR SUFFERED AS A RESULT OF THE SALE OR USE OF THE PRODUCTS. 
 
For further information and clarifications, visit our website at www.grainpro.com; email our Technical Support 
team: [email protected] or call: (+6347) 252-7884. 
 

Содержание Solar Bubble Dryer 50

Страница 1: ...GRAINPRO SOLAR BUBBLE DRYER 50 INSTRUCTION MANUAL MA4040RAD0914 9...

Страница 2: ...oad Near T Mall Nairobi KENYA Phone 254 710 933 717 Website www grainpro com Email saleseafrica grainpro com GrainPro Mexico Cto Garona No 903 Secci nTres Col Amberes 37237 Le n Gto Mexico Phone Mobil...

Страница 3: ...y charging maintenance and storage 23 Safekeeping 24 Recycling 24 Platform installation of Rodent Guard 24 7 TROUBLE SHOOTING SBD SOLAR WIRING HARNESS 25 Case 1 Battery indicator status is steady off...

Страница 4: ...that can be used to dry paddy corn coffee and others There are two GrainPro SBD50 commercial models namely SBD50 Solar which operates purely on solar energy to dry the commodity and run the ventilato...

Страница 5: ...rent top cover UV LDPE 2 2 2 Drying floor made of black reinforced PVC 610gsm 2 3 REPAIR TAPE 2 3 1 PE repair tape UV resistant and transparent for repair patching of the top cover 2 3 2 PVC duct tape...

Страница 6: ...VENTILATOR 2 8 1 12V DC ventilators Two 2 units for SBD50 Solar 2 9 VENTILATOR FRAME 2 9 1 Supporting aluminum clamp to hold the ventilator Two 2 sets 2 10 SOLAR PANELS 2 10 1 Used to convert light in...

Страница 7: ...nd toggle switch One 1 assembly 2 14 EXTENSION CORD 2 14 1 Extension wire for SBD50 Electric Ten 10 meter 2 15 AGM BATTERY OPTIONAL 2 15 1 Used to store energy to run the ventilator of SBD50 Solar 70...

Страница 8: ...frame Aluminum bars Exhaust Support Frame Aluminum bars Solar panel frame Aluminum profiles N A Ventilator 12V DC Ventilator 2 units 220V AC Ventilator 2units Solar Panel 100W 2 units N A Wiring Harne...

Страница 9: ...ing of the SBD50 and solar panel should be on a location where maximum exposure to solar radiation can be obtained 5 2 INSTALLATION 5 2 1 Set up installation a Unfold the SBD50 Take note of the foldin...

Страница 10: ...bag is located along the heating area extension of the drying floor 5 Connect the ventilator to the SBD50 body Make sure that the direction of airflow is correct see the arrow printed on the ventilato...

Страница 11: ...itry Use bolts and winged nuts as fastener and the provided screw driver to tighten d Horizontal brace One 1 piece e Bolts and winged nuts Sixteen 16 pairs 5 2 4 Exhaust support assembly COMPONENT IMA...

Страница 12: ...ree 3 pieces c Iron connector d Bolt and hex nut One 1 set 5 2 6 Tube mixer assembly COMPONENT IMAGE SEQUENCE OF ASSEMBLY a Disassembled tube mixer One 1 unit 1 Connect the three 3 parts of the tube m...

Страница 13: ...overcharging will reduce the battery capacity and shorten the battery life span e Do not short circuit the positive and negative terminal otherwise it will easily cause electric shock fire or breakdo...

Страница 14: ...If terminal voltage is lower than 12 40V boostcharge battery before installation 5 3 2 Solar Wiring Schematic Diagram for SBD50 Solar 5 3 3 Battery Connection WARNING DO NOT REMOVE SOLAR PANEL COVER U...

Страница 15: ...then displaysseven dot 7 The battery indicator also lights up otherwise check whether the connection is right 5 3 4 Solar Panel Connection a Connect the T branch MC4 connectors of the wiring harness...

Страница 16: ...Check wires with snap in bullet connectors Connect the longer red wire and longer black wire to 1 ventilator and shorter red wire and shorter black wire to other ventilator Note Shorter wires control...

Страница 17: ...ight time operations Turn off the ventilator before loading of commodities 5 3 6 Grounding Connection a Connect the grounding connector green yellow green wire to the two ventilator frames LED lamp In...

Страница 18: ...A 10 meter extension cord is provided with the SBD50 Electric Use a longer extension cord if needed Be careful to avoid possible grounding 5 4 2 Grounding Connection Make sure to connect the grounding...

Страница 19: ...in the opposite manner 5 7 FIXING WALL WITH SUPPORT LOOPS 5 7 1 There are six 6 support loops which are located at the SBD50 wall a Near the heating area b At halfway length of the drying floor c Nea...

Страница 20: ...NG 5 9 1 Rake mixer a Insert the rake mixer along the partly opened zipper liner b Close both zippers up to the rake handle c Mixing is done like a normal rake mixing in sun drying method As the rake...

Страница 21: ...of the damaged area with damp cloth and allow to dry before applying the PVC duct tape c Cut out a piece large enough to cover the damaged section to be applied at the outside surface of the drying fl...

Страница 22: ...BODY FOLDING INSTRUCTION 6 3 1 Lay down the SBD50 body on a flat surface and be sure that all the components of the body are assembled top cover shall be attached to drying floor 6 3 2 Fold the SBD b...

Страница 23: ...y distilled water Do not use tap water d Never add acids electrolyte to cells e Check your batteries once a month after installation to determine the proper watering schedule 6 4 2 Battery Inspection...

Страница 24: ...d bumps decks or roadway gutters 6 4 3 Plastic 4 LDPE Low Density Polyethylene can be recycled into compost bins paneling trash can liners and cans floor tiles and shipping envelopes 6 6 PLATFORM INST...

Страница 25: ...25 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 TROUBLE SHOOTING SBD SOLAR WIRING HARNESS 7 1 CASE 1 BATTERY INDICATOR STATUS IS STEADY OFF BATTERY NOT CONNECTED...

Страница 26: ...26 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 2 CASE 2 BATTERY INDICATOR STATUS IS SLOW FLASHING BATTERY UNDER VOLTAGE...

Страница 27: ...27 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 3 CASE 3 BATTERY INDICATOR STATUS IS QUICK FLASHING BATTERY OVER DISCHARGED...

Страница 28: ...28 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 4 CASE 4 SOLAR PANEL CHARGE INDICATOR IS STEADY OFF SOLAR PANEL NO VOLTAGE...

Страница 29: ...29 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 5 CASE 5 SOLAR PANEL CHARGE INDICATOR IS QUICK FLASHING SYSTEM OVER VOLTAGE...

Страница 30: ...30 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 6 CASE 6 LOAD INDICATOR IS STEADY ON BUT THERE IS NO OUTPUT LOAD TURNED ON BUT WITHOUT OUTPUT...

Страница 31: ...31 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 7 CASE 7 LOAD INDICATOR IS STEADY OFF LOAD TURNED OFF...

Страница 32: ...32 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 8 CASE 8 LOAD INDICATOR IS SLOWLY FLASHING AND THERE IS NO OUTPUT OVERLOAD PROTECTION...

Страница 33: ...33 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 9 CASE 9 LOAD INDICATOR IS QUICK FLASHING AND THERE IS NO OUTPUT SHORT CIRCUIT PROTECTION...

Страница 34: ...34 37 GrainPro Solar Bubble Dryer 50 Instruction Manual MA4040RAD0914 9 7 10 CASE 10 SOLAR CHARGE CONTROLLER IS NOT WORKING PROPERLY...

Страница 35: ...ied in about 8 hours from 22 to 14 moisture but the drying rate can be increased by increasing the mixing frequency The average drying rate for paddy and maize is about 1 MC per 2 hours under intermit...

Страница 36: ...gy stored in the AGM battery the ventilator will automatically stop The AGM battery is protected by the solar charge controller When the solar charge controller detects a critical energy level of the...

Страница 37: ...returning good Products to Buyer The Warranty does not cover the cost of any service work or material required for the replacement of defective Products at the site of installation GrainPro shall hav...

Отзывы: