No diameter reduction in the drainage system according to EN 1256
-
Technical regulations in relation to groundwater drainage according
to EN 752
-
Drainage systems outside of buildings according to the regulations of
the local services authorities
-
When required: Obligatory registration of the system and other man-
datory stipulations
10.
Disposal of the equipment:
11. Analogue outlet:
Your device has been fitted with an additional analogue port. This port shows the
percent values from the system control (0% – 100%) by a voltage range from 0V to
10V. The following connection values apply:
Minimal apparent ohmic resistance
: 20K Ohm
Short circuit protection
: Yes
Short circuit current
: Approx 15mA
Cable length
: maximum 200m
(shielded)
Note:
The system control is only capable of displaying whole percent values (no
fractions). These are shown on the analogue signal display. A maximum of
one digit behind the point is to be considered for the evaluation of the
pro-cent value.