Depiction 10: Sub-menu “Switching points”
Page 17
SWITCHING POINTS
key „ENTER“
VALVE ON
0-100% 10%
VALVE OFF
0-100% 12%
Supply with mains drinking water – OFF
+ / -
Supply with mains drinking water – ON
(The
numerical value is always smaller than with valve
OFF)
DW INTERVAL
0-14
DAYS
14
Flush the drinking water supply piping every
14
days. The value „0“ switches the flushing off.
+ / -
+ / -
Flushing the drinking water supply pipes for
30
seconds.
+ / -
DW DURATION
0-60 SEC 30
Cleaning the rainwater filter every
14
days
The value 0 switches the cleaning process off.
+ / -
CLEANER INTERVAL
0-14 DAYS
14
Cleaning the rainwater filter for
5
seconds
CLEANER DURATION
0-60 SEC 5
CLEANER RINSE AT
INCREMENT
2%
Cleaning the rainwater filter when the fill level
has increased by 2% after rainfall. If the fill level
continues to increase, the rinsing will be repeated
every 3 hours.
The value 0 switches the cleaning
process off.
+ / -
+ / -
Main menu level
CLEANER RINSE
WITH DW
NO
Permit the cleaning of the rainwater filter with
mains drinking water (standard:
“NO”
)
+ / -
Содержание SILENTIO