Model and Component Identification
16
334513N
Installation
Grounding
Pump:
on page 19.
Fluid lines:
use only electrically conductive lines.
Fluid supply container:
follow local code.
Accessories
Install the following required accessories in the order
shown in F
IG
. 6 and F
. 7, using adapters as neces
-
sary. See
starting on page 46.
•
Fluid filter (Y-Strainer) (included in M):
with a 60
mesh (250 micron) stainless steel element to filter
particles from the fluid before in reaches the pump.
•
Fluid shutoff valves (N):
shuts off fluid flow.
•
Pressure relief valve (F):
overload protection.
Flush Before Using Equipment
The equipment was tested with lightweight oil, which is
left in the fluid passages to protect parts. To avoid con
-
taminating your fluid with oil, flush the equipment with a
compatible solvent before using the equipment. See
, page 23.
The equipment must be grounded to reduce the risk
of static sparking and electric shock. Electric or static
sparking can cause fumes to ignite or explode.
Improper grounding can cause electric shock.
Grounding provides an escape wire for the electric
current.