Repair
334513N
35
DC Motor Brush Repair (not Hazardous Location (C1 D1) or ATEX)
1. Disconnect pump from power source.
2. Remove dust cover screws, dust cover, and o-ring.
3. Remove brush retainer using a flathead screw
-
driver.
4. Remove and replace motor brush.
5. Reinstall brush retainer.
6. Ensure o-ring is in place, and reinstall dust cover
and dust cover screws.
7. Repeat steps 2-6 for the other side of the motor.
F
IG
. 26 Motor Brush Repair
Dust
O-ring
Brush
Motor
Brush
Retainer
Cover